GIS3.3K-48L 3300w 48v solar inverter single phase for home backup

GRANKIA GIS3.3K-48L 3300w 48v solar inverter single phase for home backup, it is designed for residential backup power and solar energy applications. It supports up to 3600W PV input, a 60A maximum solar charging current, lead-acid/GEL/LiFePO4 batteries, pure sine wave output, and grid-tied operation. Its compact wall-mounted design simplifies residential installation.

Operating with a 48VDC battery system, this inverter integrates solar energy conversion, battery charging, and AC power management into one compact unit.

It supports grid-tied operation and accepts both solar PV and AC/generator input. This provides homeowners with multiple energy sources for daily electricity consumption and backup power.

What makes this configuration practical for residential applications?

Its 3600W maximum PV array capacity, 60A solar charging capability, and compatibility with three major battery chemistries provide flexibility when designing a home backup system.

The GIS3.3K-48L 3300w 48v solar inverter is particularly suitable for:

  • Residential solar backup systems.

  • Small off-grid solar installations.

  • Homes requiring battery-supported backup power.

  • Solar systems using 48V LiFePO4 batteries.

  • Applications requiring single-phase 220V/230V AC output.

3300W Rated Output for Residential Backup Applications

3300W rated AC output with 220V/230V single-phase operation.

The 48v solar inverter provides a stable power output for residential electrical loads. Its 220V/230V output configuration supports common single-phase household electrical systems.

Homeowners can use solar and stored battery energy to support essential household appliances during grid interruptions or normal solar operation.

Electrical Parameter Specification
Rated Output Power 3300W
Rated Output Current 14.3A
Nominal AC Voltage 220V/230V
Output Voltage Regulation ±4%
Frequency 50Hz/60Hz
Power Factor Unity

The 3300W capacity makes this 48V solar inverter suitable for small and medium residential backup configurations.

However, actual load compatibility depends on the combined running power and startup requirements of connected appliances.

GIS3.3K-48L Single Phase 3300W 48V Solar Inverter for Home Backup

3600W PV Input with a Wide MPPT Voltage Range

Supports up to 3600W maximum PV array power, with a 90–450VDC MPPT operating range.

The wide MPPT voltage range provides flexibility when configuring solar panel strings. The maximum PV open-circuit voltage is 500VDC.

System designers can configure the PV array according to available installation space, solar panel electrical characteristics, and daily energy requirements.

PV Input Parameter Specification
Maximum PV Array Power 3600W
Maximum PV Open-Circuit Voltage 500VDC
MPPT Operating Voltage 90–450VDC
Number of MPPT Trackers 1
Number of PV Strings 1

The inverter uses one MPPT tracker and one PV string input.

This configuration is suitable for relatively straightforward residential rooftop solar installations.

Important design consideration: The total PV string open-circuit voltage, including temperature-related voltage increases, must remain below 500VDC. The operating voltage must also stay within the specified MPPT range.

60A Solar Charging for 48V Battery Systems

Maximum solar charging current of 60A.

The charging system supports relatively high current delivery to a 48V battery bank, helping convert available solar energy into stored electrical energy.

Homeowners can store more available daytime solar energy for evening consumption and backup applications, subject to PV generation and battery charging limits.

Charging Parameter Specification
Nominal Battery Voltage 48VDC
Battery Voltage Range 40–60VDC
Default Charging Current 30A
Maximum Solar Charging Current 60A
Maximum Total Charging Current 60A
Maximum AC Charging Current 30A

The inverter supports solar and AC charging.

The maximum combined charging current is 60A, not 90A. The solar and AC charging currents must operate within the inverter’s total charging limit.

Battery charging settings should also follow the battery manufacturer’s recommended voltage, current, and temperature limits.

Multiple Battery Compatibility: Lead-Acid, GEL and LiFePO4

Compatible with three battery types: lead-acid, GEL, and lithium iron phosphate (LiFePO4).

The 48V battery architecture gives installers and system integrators flexibility in battery selection.

Users can select a battery configuration based on initial investment, expected cycling frequency, maintenance requirements, and backup duration.

Battery Type Typical Application Selection Consideration
Lead-Acid Basic residential backup Initial cost and maintenance
GEL Stationary backup applications Charging voltage and current limits
LiFePO4 Frequent solar cycling BMS compatibility and communication

LiFePO4 batteries are commonly selected for residential solar storage because of their cycle-life characteristics and integrated battery management systems.

The GIS3.3K-48L 3300w 48v solar inverter supports RS485 communication. However, the exact lithium battery communication protocol and BMS compatibility must be confirmed before installation.

Do not assume that every 48V lithium battery is automatically compatible.

 

Grid and Generator Input Flexibility

Supports AC input from the grid or a compatible generator.

The 48v solar inverter accepts an AC input voltage range of 170–280VAC and automatically detects 50Hz or 60Hz frequency operation.

Users have an additional charging and power supply option when solar generation is insufficient.

AC Input Parameter Specification
Nominal Voltage 220V/230V
Acceptable Voltage 170–280VAC
50Hz Frequency Range 47–55Hz
60Hz Frequency Range 57–65Hz
Maximum AC Charging Current 30A

This flexibility is particularly useful for residential solar systems installed in areas with unstable grid electricity or limited sunlight.

Generator compatibility should be checked against the generator’s voltage regulation, frequency stability, and available output capacity.

RS485 Communication and Optional Remote Monitoring

Integrated RS485 communication with optional Wi-Fi or GPRS connectivity.

The communication interface provides a foundation for system monitoring and communication with compatible external devices.

Installers and system operators can monitor operating information and potentially perform remote system management when supported communication accessories and software are available.

Communication Feature Specification
Standard Communication RS485
Optional Connectivity Wi-Fi / GPRS
Display LCD
Status Indicators LED

The optional connectivity provides additional monitoring possibilities.

Before deployment, confirm the availability of the corresponding monitoring platform, communication protocol, and accessories.

Technical Specifications

The following table summarizes the main electrical and installation parameters of the GIS3.3K-48L.

Parameter Specification
Model GIS3.3K-48L
Rated Output Power 3300W
Battery Voltage 48VDC
AC Output 220V/230V
Phase Single Phase (L+N+PE)
Maximum PV Array Power 3600W
Maximum PV Voltage 500VDC
MPPT Voltage Range 90–450VDC
Maximum Solar Charging Current 60A
Maximum AC Charging Current 30A
Maximum Combined Charging Current 60A
Surge Power 6600VA
Output Waveform Pure Sine Wave
Maximum Efficiency ≥93.8%
Transfer Time 10ms
Battery Compatibility Lead-acid / GEL / LiFePO4
Communication RS485
Protection Degree IP21
Dimensions 269 × 100 × 372mm
Weight 7.2kg

Solar Charging vs. AC Charging

The GIS3.3K-48L supports two charging sources.

Charging Feature Solar Charging AC Charging
Charging Source PV panels Grid/generator
Maximum Current 60A 30A
Energy Source Solar energy AC electricity
Main Application Solar energy storage Backup battery charging

The maximum combined charging current is 60A.

This distinction matters when configuring simultaneous charging from PV and AC sources.

 

How to Set Grid-tied Function

To enable the photovoltaic grid-connected power generation function on the 48v hybrid solar inverter, you configure Parameter [27] in the LCD settings menu.

Before changing grid-tie settings, make sure your grid connection and protection devices are properly wired and comply with local utility rules, as feeding power back to the grid involves live AC mains and high-voltage DC solar inputs.

Step-by-Step: Setting Parameter [27] on the LCD Screen

Enter the LCD Settings Menu

Press the ESC key on the display panel to enter the Settings menu.

Select Parameter [27]

Press the UP and DOWN keys until parameter code 27 (Photovoltaic grid-connected power generation function) is selected.

Edit and Confirm the Grid-Tie Mode

Press ENTER to enter parameter editing mode, then use UP and DOWN to choose your desired grid-tie option:

  • TOG: Feeds excess photovoltaic energy to the grid when the battery is full or no battery is connected.
  • TOL: Supplies load power using both photovoltaic (PV) energy and the grid (city power).
  • DIS (Default): Disables the photovoltaic grid-connected power generation function. Press ENTER to save the setting.

Exit the Settings Menu

Press ESC to exit the Settings menu and return to normal operation monitoring.

Running without a battery in TOG or TOL mode

When running without a battery on the hybrid inverter (with Parameter [27] set to TOG or TOL), the unit relies on its battery-less output/bypass capability and grid connection to keep loads running and handle solar energy.

How Each Mode Behaves Without a Battery

  • TOG (Photovoltaic Grid-Connected Export): When the battery is full or not connected, excess photovoltaic energy beyond local load demand is fed back to the grid. 
  • TOL (PV + Grid Load Supply): Load power is supplied using both photovoltaic (PV) energy and utility power. When solar input is insufficient for the load, the utility grid makes up the difference—and the inverter can bypass/supply loads directly from the grid when needed.

What to Expect & Watch For Without a Battery

  1. No Battery Energy Buffer: Without a battery connected, there is no stored energy to ride through PV drops or grid outages, and battery-less operation is designed for special scenarios such as battery trip, battery damage, or running without a battery cell connected.
  2. Battery Disconnected Alarm: Because no storage battery is present, the inverter may trigger a “battery is not connected to the alarm” indication. Check the battery line and external battery breaker if you intended to have a battery connected.
  3. Grid & PV Dependency: Grid-tie operation (TOG / TOL) requires a valid utility grid connection alongside PV input. If the grid is unstable or weak, the manual notes that APL (wide-voltage AC input) mode helps keep operation stable.

How They Differ in Practice

When running without a battery on the hybrid inverter, whether you should choose TOG or TOL in Parameter [27] depends on whether you want to export excess solar power back to the utility grid or simply share your local load between solar and the grid.

Feature TOG TOL
Definition When the battery is filled or not connected to the cell, the photovoltaic energy of the excess local load is fed to the grid. The load power is provided by the PV and utility grid power.
Excess Solar Power Sent back into the utility grid when solar generation exceeds local load demand. Not explicitly defined as feeding back to the grid; focuses on powering the local load using both PV and utility power.
Best Use Case Without a Battery Grid-export / net-metering setups where exporting surplus solar energy is allowed and desired. Self-consumption setups where PV and utility power jointly supply your connected appliances without exporting to the grid.

Installation, Safety and International Standards

Correct installation is necessary to achieve the specified electrical performance and maintain system safety.

The GIS3.3K-48L specifications reference the following standards:

Standard Scope
IEC 62109-1 Safety of power converters for photovoltaic systems – General requirements
IEC 62109-2 Particular requirements for inverter safety
IEC/EN 61000-6-1 EMC immunity for residential, commercial and light-industrial environments
IEC/EN 61000-6-3 EMC emission requirements for residential environments
IEC 62321 Determination of regulated substances in electrotechnical products

The product specification also lists CE and RoHS certifications/compliance.

For international projects, buyers should request the relevant declarations and test documentation to verify the exact applicable standards and certification scope.

Installation Considerations

Before commissioning, installers should verify:

  • Correct battery polarity and DC cable sizing.

  • Appropriate DC and AC circuit protection.

  • PV string voltage under minimum-temperature conditions.

  • Battery charging and discharging limits.

  • Protective earthing and grounding.

  • Adequate ventilation and installation clearance.

  • Compatibility with the local grid voltage and frequency.

Its specified operating temperature range is -10°C to 55°C.

Frequently Asked Questions (FAQ)

Yes. The GIS3.3K-48L hybrid solar inverter provides 3300W rated single-phase AC output at 220V/230V. It supports 48V batteries, up to 3600W PV input, and a 10ms transfer time, making it suitable for residential backup applications within its rated capacity.
The GIS3.3K-48L supports a maximum PV array power of 3600W. The actual number of panels depends on individual panel wattage, Voc, operating voltage, and string configuration. The maximum PV open-circuit voltage is 500VDC, and the MPPT range is 90–450VDC.
Yes. The GIS3.3K-48L supports 48V LiFePO4 batteries, as well as lead-acid and GEL batteries. However, the battery's charging voltage, maximum current, and BMS communication compatibility must be verified before installation.
Yes. It supports AC/generator input at 220V/230V nominal voltage, with an acceptable input range of 170–280VAC. It also supports automatic 50Hz/60Hz frequency detection and up to 30A AC charging current.
No. The GIS3.3K-48L does not support parallel operation. If a project requires higher output power or future parallel expansion, select an inverter model with a manufacturer-confirmed parallel operation function.

 

The Articles You may Like

 

Exit mobile version
Your Privacy

GRANKIA stores and retrieves information on your browser through cookies. This information helps ensure the website functions properly and may relate to you, your preferences, or your device. Additionally, we utilize cookies to enhance your browsing experience with personalized content. It's important to note that blocking certain types of cookies could impact your website experience and the services we offer. For a more comprehensive overview of the cookies we use, please consult our Privacy Policy.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Analytics

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.