GRANKIA Electric (GUANGDONG) Co., Ltd.

GLT3310 3 phase backup power low frequency online ups 10kva

GRANKIA GLT3310 3 phase backup power low frequency online ups 10kva is a high-performance three-phase uninterruptible power supply. It is designed to deliver stable and reliable backup power for critical applications. Engineered with advanced low frequency double-conversion technology, it ensures continuous clean power. It also provides maximum protection against voltage fluctuations, surges, and outages.

Low frequency double conversion 3-phase online UPS 10kVA delivers advanced technology designed to enhance both performance and reliability. Its online double conversion architecture provides complete isolation from utility power, ensuring continuous protection against all power quality disturbances.

GLT3310 3 phase backup power low frequency online ups 10kva

Online UPS 10KVA Features

True Online Double Conversion – Provides continuous power conditioning for maximum system reliability.

Three-Phase Input/Output – Ensures stable power distribution for industrial, commercial, and IT environments.

Low Frequency Design – Delivers enhanced durability, higher overload capability, and robust performance in harsh conditions.

LCD Display – Real-time monitoring of operating status, load, battery condition, and alarms.

Comprehensive Protection – Guards against short circuit, overload, over-temperature, and battery under-voltage.

Parallel Redundancy Support – Allows multiple UPS units to be connected in parallel for higher capacity or N+1 redundancy.

Eco Mode Function – Optional high-efficiency mode for energy-saving operation under stable power conditions.

3 Phase UPS Start-Up Procedures

Verify Input Power

Confirm that the voltage and frequency from the power distribution to the UPS terminals are within the normal range.

Turn On Bypass and Output Switches

Switch on SWBY (bypass) and SWOUT (output).
The UPS will operate in bypass mode.
The BYIN and BYPASS indicator LEDs on the panel will turn green and remain steadily lit.

Turn On Main Input Switch

Turn on SWIN (main circuit).
After approximately 30 seconds, the UPS will transfer to mains inverter mode.
The INPUT and INV LEDs will be green and steadily on. The yellow BYPASS LED will turn off. The BATTERY LED will flash.

Turn On the Battery Switch

After confirming that the battery polarity is correctly connected, switch on the battery breaker.
The UPS will automatically detect the battery capacity.
The INPUT and INV LEDs will remain green and on, and the yellow BATTERY LED will turn off.

The Articles You may Like

 

Exit mobile version