GIS5K-48L 5kw solar inverter single phase pure sine wave output

Hybrid Solar Inverter | 5000W | 48VDC | Max. PV Power: 8000W | Max. Charge Current: 100A

SKU: GIS5K-48L Category:

GRANKIA GIS5K-48L 5kw solar inverter single phase pure sine wave output, an 8kW maximum PV input, and a 100A maximum solar charging current. Operating with 48V lead-acid, gel, or LiFePO4 batteries, it supports grid-tied operation, AC charging, and flexible solar energy management for residential applications.

Residential solar systems require more than basic DC-to-AC conversion. They need sufficient PV input capacity, reliable battery charging, stable AC output, and compatibility with different energy sources.

The GIS5K-48L addresses these requirements through an integrated solar inverter architecture. It combines a 5,000W rated AC output, MPPT solar charging, battery management, and grid-connected operation in one compact unit.

As a 48V single-phase solar inverter, it is designed for residential photovoltaic installations, backup power systems, and small-scale energy storage applications.

Its main technical characteristics include:

  • 5,000W rated output power.
  • Single-phase L+N+PE AC output.
  • 8,000W maximum PV array power.
  • 90–450VDC MPPT operating voltage.
  • 500VDC maximum PV open-circuit voltage.
  • 100A maximum solar charging current.
  • 100A maximum total battery charging current.
  • Pure sine wave AC output.
  • 10,000VA surge power.
  • 10ms transfer time.
  • 48V battery compatibility.
  • Grid-tied operation support.

Table of Contents

High PV Input Capacity: Supports Up to 8kW Solar Panels

8,000W Maximum PV Array Power

The GIS5K-48L 5kw solar inverter supports a maximum photovoltaic array power of 8,000W, paired with a 5,000W rated AC output.

This allows the installed PV array capacity to exceed the inverter’s rated output power.

GIS5K-48L 5kW Solar Inverter with 100A Solar Charging for Home Energy Systems

 

Greater Solar Energy Harvesting Potential

A larger PV array provides additional solar generation capacity, particularly during periods of reduced solar irradiance, such as early mornings, late afternoons, and cloudy conditions.

The 90–450VDC MPPT operating range also provides flexibility when configuring solar panel strings.

Its PV input specifications are:

Parameter Specification
Maximum PV Array Power 8,000W
Maximum PV Open-Circuit Voltage 500VDC
MPPT Operating Voltage 90–450VDC
Maximum Solar Charging Current 100A
Number of MPPT Trackers 1
Number of PV Strings 1

More Flexible Residential PV System Design

Installers can configure a solar array with up to 8kW of rated module capacity, subject to the inverter’s voltage, current, and PV configuration limits.

This is useful for residential projects where available roof space and daily energy consumption justify a larger solar array.

Important design consideration: The 500VDC maximum PV open-circuit voltage must never be exceeded, including under the lowest expected ambient temperature. The single MPPT tracker and single-string specification must also be considered when designing the PV layout.

100A Solar Charging: Efficient 48V Battery Charging

Maximum 100A Solar Charging Current

The GIS5K-48L integrates an MPPT solar charge controller with a maximum solar charging current of 100A.

It also supports up to 100A maximum total battery charging current.

High-Capacity Charging for 48V Battery Systems

A 100A charging capability allows the inverter to deliver substantial charging current to compatible 48V battery banks.

The system can utilize available solar generation to replenish stored energy while supporting configurable battery charging requirements.

For example, at a nominal 48V battery voltage, a theoretical 100A charging current corresponds to approximately 4.8kW of DC charging power.

Actual charging power depends on battery voltage, available PV power, conversion losses, temperature, and battery charging limits.

Reduced Dependence on Grid Charging

With sufficient solar generation and appropriately sized batteries, homeowners can increase daytime energy storage and reduce the need for grid-based battery charging.

The inverter also supports a maximum AC charging current of 60A, offering an alternative charging source when solar energy is insufficient.

Charging Parameter Specification
Maximum Solar Charging Current 100A
Maximum AC Charging Current 60A
Maximum Total Charging Current 100A
Default Charging Current 30A
Nominal Battery Voltage 48VDC
Battery Voltage Range 40–60VDC

Pure Sine Wave Output: Stable AC Power for Household Appliances

5,000W Single-Phase Pure Sine Wave Output

The GIS5K-48L delivers 5,000W rated AC output through a single-phase L+N+PE connection.

Its output waveform is pure sine wave, with a nominal voltage of 220VAC or 230VAC and an output frequency of 50Hz or 60Hz.

Compatibility with Common Residential Loads

Pure sine wave output provides an AC waveform suitable for a wide range of household electrical equipment.

Typical applications include:

  • Refrigerators and freezers.
  • LED lighting systems.
  • Computers and office equipment.
  • Televisions and communication devices.
  • Household water pumps.
  • Fans and air-conditioning equipment, subject to starting-current requirements.

The inverter also provides a maximum surge power of 10,000VA, allowing it to accommodate temporary startup demands from certain inductive loads.

More Reliable Power for Everyday Applications

For homeowners, stable AC output helps maintain the operation of common electrical appliances.

For solar installers and system integrators, the 5kW rated output provides a defined capacity for residential load planning.

AC Output Parameter Specification
Rated Output Power 5,000W
Rated Output Current 21.7A
Surge Power 10,000VA
Output Voltage 220/230VAC ±4%
Output Frequency 50/60Hz ±0.3Hz
Waveform Pure Sine Wave
Power Factor Unity
Transfer Time 10ms
Maximum Efficiency ≥93.0%

System sizing reminder: The 5,000W rated output is the continuous power rating, while the 10,000VA surge rating represents a temporary peak capability. Motor starting performance must be evaluated against the inverter’s actual surge duration and overload characteristics.

48V Multi-Chemistry Battery Compatibility

Supports Lead-Acid, Gel, and LiFePO4 Batteries

The GIS5K-48L operates with a nominal 48VDC battery system.

It supports three battery categories:

  • Lead-acid batteries.
  • Gel batteries.
  • Lithium iron phosphate (LiFePO4) batteries.

The specified battery voltage operating range is 40–60VDC.

Flexible Battery Selection

Different residential projects have different energy storage budgets, operating requirements, and battery preferences.

Compatibility with multiple battery types gives installers greater flexibility when designing solar energy systems.

For example:

Battery Type Typical Application Main Consideration
Lead-acid Cost-sensitive backup systems Maintenance and usable capacity
Gel Residential backup applications Charging voltage and temperature limits
LiFePO4 Modern residential energy storage BMS compatibility and communication

Adaptable Energy Storage Configurations

Customers can select an appropriate 48V battery bank based on their required backup duration, energy consumption, and project budget.

For lithium battery applications, battery BMS compatibility must be verified before installation.

The GIS5K-48L 5kw solar inverter provides an RS485 communication interface. However, the exact supported lithium battery protocols and compatible battery models should be confirmed with the manufacturer.

Battery charging voltage, current limits, and protection settings must follow the battery manufacturer’s specifications.

GIS5K-48L 48V 5kW Solar Inverter for Residential Solar and Battery Storage Systems

 

Grid and Generator Input: Flexible AC Charging and Power Management

Wide AC Input Voltage Range

The GIS5K-48L hybrid solar inverter supports AC input from 170VAC to 280VAC.

It accepts nominal AC input voltages of 220VAC and 230VAC, with automatic 50Hz/60Hz frequency sensing.

The AC input specifications are:

Parameter Specification
Nominal AC Input Voltage 220/230VAC
Acceptable Voltage Range 170–280VAC
50Hz Frequency Range 47–55Hz
60Hz Frequency Range 57–65Hz
Maximum AC Charging Current 60A
Grid-Tied Operation Supported

Adaptability to Different AC Supply Conditions

The wide input voltage range allows the inverter to accommodate variations in grid or compatible generator supply conditions.

The 60A maximum AC charging current also provides an additional battery charging source.

This can be useful when:

  • Solar generation is insufficient.
  • Battery state of charge is low.
  • A generator is used as an auxiliary power source.
  • Additional battery charging is required during periods of limited sunlight.

More Flexible Energy Source Management

By combining PV input, battery storage, and AC input, the inverter provides multiple energy sources for residential installations.

Its grid-tied operation support also makes it suitable for projects requiring grid-connected functionality.

However, detailed grid-export capabilities, anti-islanding protection configuration, export control, and applicable grid interconnection approvals must be verified for the target market.

Grid-tied operation support alone does not establish approval for unrestricted grid export.

Fast Transfer Time and High Conversion Efficiency

10ms Transfer Time and ≥93% Maximum Efficiency

The GIS5K-48L solar inverter 5kw specifies a 10ms transfer time and a maximum efficiency of at least 93%.

These parameters are important when evaluating inverter performance in residential backup and solar power applications.

Reduced Power Interruption and Lower Conversion Losses

A 10ms transfer time helps reduce interruptions when the inverter switches between supported power sources.

Its maximum conversion efficiency of ≥93% indicates that the inverter can convert DC energy into AC power with limited conversion losses under applicable test conditions.

Better Utilization of Available Energy

Higher conversion efficiency helps reduce energy losses during power conversion.

Fast transfer also helps support connected equipment during source switching.

Actual efficiency depends on operating load, battery voltage, temperature, and input conditions. Transfer performance should be evaluated against the requirements of sensitive equipment.

Communication, Monitoring, and Installation

RS485 Communication and Optional Wireless Connectivity

The GIS5K-48L includes an RS485 communication interface.

Optional Wi-Fi and GPRS configurations are available.

Its LCD display and LED indicators provide local access to operating information and system status.

Convenient System Monitoring

RS485 provides a communication interface for compatible monitoring equipment and battery communication systems.

Optional wireless connectivity can support remote monitoring, subject to the selected hardware and software platform.

Easier Operation and Maintenance

Installers can use the display and supported communication functions to monitor system operation and facilitate troubleshooting.

The main installation and environmental specifications are:

Parameter Specification
Installation Method Wall-mounted
Protection Rating IP21
Operating Temperature -10°C to 55°C
Storage Temperature -20°C to 60°C
Operating Humidity 5%–95%, non-condensing
Maximum Operating Altitude 2,000m
Dimensions (W×D×H) 290×110×380mm
Net Weight 7.2kg
Display LCD + LED Indicators

The compact housing and 7.2kg weight simplify handling and wall-mounted installation.

IP21 protection is intended for indoor environments. The inverter should be installed in a dry, ventilated location with adequate clearance for heat dissipation.

Above 2,000m altitude, output derating is required.

Typical Applications

The GIS5K-48L can be considered for several types of residential and small-scale solar installations.

GIS5K-48L 5kW Single Phase Solar Inverter with Pure Sine Wave Output

Residential Solar Power Systems

Its 5kW rated output and 8kW maximum PV input make it suitable for residential photovoltaic systems with moderate electricity demand.

Home Backup Power Systems

With 48V battery compatibility and a 10ms transfer time, it can support backup power configurations for selected household loads.

Solar Systems with LiFePO4 Batteries

The 48V battery architecture supports LiFePO4 applications, subject to confirmation of BMS communication and charging compatibility.

Grid-Connected Solar Applications

The inverter supports grid-tied operation and accepts a wide AC input voltage range.

Project developers should confirm local grid interconnection requirements and the specific grid-export functions before system deployment.

Small Commercial and Remote Applications

The 5kW single-phase output can also be considered for small offices, remote facilities, and other installations where the electrical load remains within the inverter’s operating limits.

International Standards and Product Compliance

Electrical safety and electromagnetic compatibility are important considerations when selecting a solar inverter for international distribution.

According to the supplied product specifications, the GIS5K-48L lists the following certifications and compliance standards:

Category Listed Certification / Standard
Product Certifications CE, RoHS
EMC IEC/EN 61000-6-1
EMC IEC/EN 61000-6-3
Electrical Safety IEC 62109-1
Electrical Safety IEC 62109-2
Material Compliance IEC 62321

IEC 62109-1 and IEC 62109-2 address safety requirements for power converters used in photovoltaic power systems.

The IEC/EN 61000 series addresses electromagnetic compatibility requirements, while IEC 62321 covers methods for determining certain regulated substances in electrotechnical products.

These standards provide a technical reference for product evaluation and international market access.

For specific export markets, buyers should request the corresponding test reports, declarations of conformity, and applicable certificates to verify the exact product model and certification scope.

 

Frequently Asked Questions (FAQ)

Can I connect multiple GIS5K-48L units in parallel for three-phase or 10kW output?

No. The GIS5K-48L is engineered strictly as a standalone single phase pure sine wave 5kW solar inverter and does not support parallel stacking. If your site requires 10kW+ capacity or three-phase output, select a dedicated parallel-capable hybrid inverter series.

What is the maximum solar panel wattage this 48V hybrid solar inverter supports?

You can connect up to 8000W of solar panels to the single MPPT tracker. Ensure the string's open-circuit voltage (Voc) stays below 500VDC at the lowest expected ambient temperature, and keep the operating voltage within the 90–450VDC MPPT range.

Can this 5kW single phase solar inverter work with LiFePO4 batteries?

Yes. LiFePO4 batteries are listed as compatible battery types. However, the battery voltage settings, charging current limits, and RS485 BMS communication protocol must be verified with the battery manufacturer and inverter supplier before installation.

Can I use a fuel generator as the backup AC input source?

Yes. Because the AC input accepts a wide voltage window (170–280VAC) and auto-senses 50Hz or 60Hz frequencies, it tolerates voltage and frequency fluctuations common in backup diesel or gasoline generators while providing up to 60A of AC battery charging.

Does the GIS5K-48L support grid-tied operation and generator charging?

The specifications confirm grid-tied operation support. The inverter accepts 170–280VAC input and supports a maximum AC charging current of 60A. Generator compatibility should be checked against the generator's voltage, frequency, waveform, and power characteristics. Grid export functions and local grid approvals should also be confirmed.

 

The Articles You may Like

 

Model GIS5K-48L
Rated Output Power 5000W
PHASE Single phase, L+N+PE
Grid-tied Operation Supported
Parallel Capability No
PV INPUT (DC)
Max. PV Array Power 8000W
Max. Solar Charging Current 100A
Max. PV Open Circuit Voltage 500VDC
MPPT Operating Voltage Range 90-450VDC
Number of MPPT Trackers / Strings 1/1
AC / GENERATOR INPUT
Nominal Voltage 220VAC/230VAC
Acceptable Voltage Range 170VAC – 280VAC
Frequency Range 50Hz: 47-55Hz / 60Hz: 57-65Hz (Auto-sensing)
Max. AC Charging Current 60A
AC OUTPUT
Rated Output Power 5000W
Rated Current 21.7A
Surge Power 10000VA
Nominal Voltage 220VAC/230VAC ± 4%
Frequency 50Hz / 60Hz ±0.3Hz(Auto-sensing)
Waveform Pure Sine Wave
Transfer Time 10ms
Power Factor Unity Power Factor
Max. Efficiency ≥ 93.0%
BATTERY
Compatible Battery Types Lead-acid / Gel / LiFePO4
Nominal Battery Voltage 48VDC
Battery Voltage Range 40-60VDC
Default Charging Current 30A
Max. Total Charging Current 100A
INTERFACE & COMMUNICATION
Communication Ports RS485
Optional Models Wi-Fi / GPRS
Display LCD + LED Indicators
ENVIRONMENT
Installation Method Wall-mounted
Operating Temperature -10℃ ~ 55℃
Storage Temperature -20℃ ~ 60℃
Operating Humidity 5%~95%(No condensation)
Max. Operating Altitude ≤2000m (Derating above 2000m)
Protection Degree IP21 (Indoor installation)
MECHANICAL
Dimension, WxDxH (mm) 290x110x380
Weight (Kg) 7.2
CERTIFICATIONS
Safety & EMC Certificates CE, RoHS
Compliance Standards IEC/EN 61000-6-1/3, IEC 62109-1, IEC 62109-2, IEC 62321
GDPR GRANKIA
Your Privacy

GRANKIA stores and retrieves information on your browser through cookies. This information helps ensure the website functions properly and may relate to you, your preferences, or your device. Additionally, we utilize cookies to enhance your browsing experience with personalized content. It's important to note that blocking certain types of cookies could impact your website experience and the services we offer. For a more comprehensive overview of the cookies we use, please consult our Privacy Policy.