Split Phase Inverter | 5000W | 110V or 120V(L-N) / 220 or 240V(L1-L2) | 48VDC | Max. PV: 7500W
GRANKIA GNA5K-LV best 48v dc to ac 5kw 120 240 split phase inverter provides reliable power conversion for various applications. It can provide reliable and efficient power conversion from your solar panels to usable AC electricity.
The 5kW 120/240 split-phase inverter operates at a nominal voltage of 48V and supports split-phase configurations, making it suitable for a variety of electrical setups.
The 48v split phase inverter boasts an impressive efficiency rating, ensuring minimal energy loss during the conversion process. This means more power for your devices and lower energy costs.

The 5kw solar split phase power inverter is equipped with four independent Maximum Power Point Tracking (MPPT) channels. This allows for optimal energy harvesting from multiple solar panel arrays, even if they are oriented in different directions or experiencing varying levels of sunlight. This feature maximizes energy production and enhances overall system efficiency.
The GNA5K-LV hybrid solar inverter 5kw produces a pure sine wave output, which is essential for sensitive electronics and appliances. This ensures that devices operate smoothly without interference or damage.
This solar inverter provides a split phase output of 120/240V, making it compatible with a wide range of appliances and equipment. Whether you need to power small electronics or larger machinery, the GNA5K-LV 5kW hybrid solar inverter can handle it all.
The 48v 5kw split phase inverter is equipped with an advanced cooling system that prevents overheating during operation. This ensures optimal performance and extends the lifespan of the inverter.
The solar inverter supports various input sources, including solar panels, batteries, and other DC power sources, making it a flexible choice for different energy setups.
Users can customize settings such as output voltage, frequency, and battery charging parameters, allowing for tailored performance based on specific needs.



The GNA5K-LV 48V DC to AC 5kW split phase inverter is versatile and can be used in a variety of applications.
Off-Grid Solar Systems
Ideal for solar power setups, the GNA5K-LV can convert the DC output from solar panels into usable AC power for homes and businesses, enabling energy independence.
Backup Power Supply
In the event of a power outage, this inverter can serve as a reliable backup power source, ensuring that essential appliances and systems remain operational.
Residential Use
The inverter can power household appliances, lighting, and electronics, making it suitable for homes that require a stable and efficient power supply.
Cabins and Remote Locations
For off-grid cabins or remote locations without access to the electrical grid, the GNA5K-LV provides a reliable power solution for lighting, heating, and other essential services.
Smart Home Integration
The inverter can be integrated into smart home systems, allowing for automated energy management and monitoring, enhancing energy efficiency.
| Model | GNA5K-LV |
| Max. PV INPUT POWER | 7500W |
| Rated Output Power | 5000W |
| Dimension, D x W x H (mm) | 240x450x820 |
| Net weight (kg) | 50 |
| PV INPUT (DC) | |
| Nominal DC Voltage/Max. DC Voltage | 500VDC |
| MPPT Voltage Range | 120VDC~500VDC |
| Max. DC INPUT Current | 14A |
| Max. DC Short-circuit Current | 22A |
| No. of MPPT Trackers | 4 |
| No. of String per MPPT Tracker | 1/1 |
| AC OUTPUT (ON-GRID) | |
| Rated Output Power | 5000W |
| Max. AC Output Power | 5500W |
| Nominal Output Voltage | split phase: 110V/220V, 120V/240V; single phase: 240V |
| Output Frequency | 60Hz (55 – 65Hz) |
| Rated Output Current | 20.8A |
| Max. AC Output Current to Grid | 22.9A |
| Max. Grid Passthrough Current | 100A |
| Total Harmonic Distortion(THDi) | < 3% |
| AC OUTPUT (Backup) | |
| Rated Output Power | 5000W |
| Nominal Output Voltage | 120V(L-N) / 240V(L1-L2) |
| Output Frequency | 60Hz |
| Rated Output Current | 20.8A |
| Transfer Time | < 20ms |
| Output Power Factor | 0.8 leading~0.8 lagging |
| Total Harmonic Distortion(THDu) | <2% |
| EFFICIENCY | |
| Battery to Load Efficiency | 95.2% |
| PV to Grid Efficiency | 97.2% |
| Euro Efficiency | 96.5% |
| MPPT Efficiency | 99.9% |
| PV to Battery Charging Efficiency | 96.1% |
| Grid to Battery Charging Efficiency | 95.0% |
| BATTERY & CHARGER | |
| Battery Type | Lead-acid or Lithium-ion |
| Nominal DC Voltage | 40VDC – 60VDC |
| Max. Charging Voltage | 58V |
| Max. Charging/Discharging Current | 120A/120A |
| Charging Curve | 3 Stages / Equalization |
| Charging Strategy for Li-battery | Self-adaption to BMS |
| INTERFACE | |
| Communication Port | RS485, WLAN, WiFi / 4G (option) |
| BMS | RS485, CAN |
| EMS | RS485, CAN |
| Meter | RS485, CAN |
| ENVIRONMENT | |
| Operating Temperature | -25°C to 60°C |
| Relative Humidity | 0 ~95%(non-condensing) |
| Altitude | 0~4,000m (>2000m derating) |
| Cooling | Fan |
| Noise | < 38dB |
| Self-consumption | < 25W |
| Protection Degree | IP65 / NEMA 3R |
| CERTIFICATION STANDARDS | |
| Grid Regulation | IEEE 1547, IEEE 2030.5, Hawaii rule 14H, Rule 21 phase I,II,III |
| Safety EMC / Standard | FCC part 15 class B, UL1741SA all options, UL1699B, CSA 22.2 |