IP65 Hybrid Solar Inverter | 5000W | 2MPPTs: 18A + 18A | 48VDC | Max. Charging: 110A
GRANKIA HC1050EH48L is a single-phase hybrid inverter 5kW rated at 5000W output, supporting 10kW PV input, 48VDC lithium/lead-acid batteries, and 97.60% max efficiency. IP65-rated, parallelable up to 15 units, transfer time ≤10ms. Built for reliable solar battery backup in homes and small commercial sites.
The HC1050EH48L is a transformerless, single-phase hybrid inverter 5kW system. It is designed for homes, villas, small commercial buildings, and off-grid applications.
It merges four functions into one unit:
Unlike traditional solar inverters, this hybrid architecture enables users to maximize solar self-consumption, store excess energy, and maintain power availability during grid interruptions.
The IP65 hybrid solar inverter supports:
It is optimized for customers seeking a reliable 5kW hybrid solar inverter with battery backup for energy independence and reduced electricity costs.

Modern households face several energy challenges:
Traditional grid-connected solar systems cannot provide backup power when the grid fails.
A standard solar inverter shuts down during outages due to anti-islanding requirements.
A hybrid inverter solves this limitation by combining:
This allows households to maintain critical loads even during grid failures.
The HC1050EH48L provides a complete solar battery backup system inverter solution.
The system automatically determines the optimal energy source:
| Operating Condition | Energy Priority |
| Strong sunlight | Solar → Load → Battery Charging |
| Low solar generation | Battery → Load |
| Battery low | Grid/Generator → Load |
| Grid failure | Battery → Backup Loads |

This intelligent switching improves renewable energy utilization and enhances household energy security.
| Model | HC1050EH48L |
| Rated Output Power | 5kW |
| PV Input Power | Max. 10kW (5kW + 5kW) |
| Battery Voltage | 48VDC |
| Battery Voltage Range | 40-60VDC |
| Phase Configuration | Single Phase Input / Single Phase Output |
| PV Maximum Voltage | 500VDC |
| MPPT Voltage Range | 120VDC-425VDC |
| MPPT Trackers | 2 MPPT |
| Maximum Efficiency | 97.60% |
| MPPT Efficiency | >99% |
| Protection Rating | IP65 |
| Installation | Wall-mounted |
| Weight | 14.5kg |
| Warranty | 5 Years |
The IP65 hybrid inverter accepts up to 10kW PV input (5kW + 5kW) across two independent MPPT trackers, with an MPPT voltage range of 120–425VDC.
Oversizing the PV array relative to the 5kW inverter rating captures more usable energy during low-light, dawn, and dusk hours.
Homeowners get more daily kWh harvested per installed inverter, reducing payback period without buying a larger inverter.
Supports lead-acid, gel, and lithium-ion batteries at 48VDC nominal voltage (40–60VDC range), with max charge/discharge current of 110A.
Installers are not locked into one battery chemistry or one brand, simplifying system design and future battery upgrades.
This flexibility makes the HC1050EH48L a practical 48v hybrid inverter for battery backup projects ranging from retrofit lead-acid systems to new lithium installations.

When solar power generation exceeds the load demand and battery charging capacity, the excess electricity can flow back to the grid.
If local power regulations or utility agreements prohibit exporting power to the grid, the inverter supports external anti-backflow control.
This feature allows you to limit or completely block power feedback into the grid depending on your site configuration.
The HC1050EH48L supports:
AC input parameters:
| Parameter | Specification |
| Nominal Voltage | 220/230/240VAC |
| Voltage Range | 150-290VAC |
| Frequency | 50Hz/60Hz |
| Maximum AC Input Current | 40A |
When solar energy is insufficient and battery capacity is low:
Generator input can automatically support household loads.
This provides additional reliability for:
The HC1050EH48L supports parallel operation of up to:
15 units
Inverter models designated with a “P” suffix are equipped with parallel communication hardware. You can connect up to 15 units in parallel to scale total output power and battery capacity for larger residential or commercial installations. (Pm – Master; P – Slave).
Parallel-enabled units synchronize AC output frequency, voltage phase, and real-time load distribution via dedicated communication lines (RS485/CAN).
This enables flexible system expansion.
Example:
| System Configuration | Total Output Capacity |
| 1 × HC1050EH48L | 5kW |
| 5 × HC1050EH48L | 25kW |
| 10 × HC1050EH48L | 50kW |
| 15 × HC1050EH48L | 75kW |
Parallel capability allows users to:
This reduces initial investment pressure while keeping future scalability.
The HC1050EH48L adopts an IP65 protection enclosure, allowing reliable operation in demanding environments.
The IP65 rating means:
This makes it an ideal IP65 hybrid inverter for residential solar systems where equipment may be installed in garages, utility rooms, exterior walls, or protected outdoor areas.
| Environmental Parameter | Specification |
| Protection Level | IP65 |
| Operating Temperature | -40°C to 60°C |
| Humidity Range | 0-95% RH (Non-condensing) |
| Maximum Altitude | <3000m |
| Noise Level | <55dB |
| Cooling Method | Intelligent Fan Cooling |
| Installation Method | Wall-mounted |
The inverter is designed for:
When ambient temperature exceeds 45°C, the system automatically applies power derating to maintain safe operation.
The inverter provides multiple communication interfaces:
Standard:
Optional:
The integrated:
provides real-time information:
With optional communication modules, installers and users can remotely monitor:
This improves operation efficiency and simplifies maintenance.
Allows users to schedule specific time windows for battery charging and discharging.
Off-Peak Hours: The battery charges from solar or low-cost grid electricity.
Peak Hours: The battery discharges to power loads, reducing expensive peak-rate energy consumption from the grid.

The HC1050EH48L IP65 solar inverter integrates multiple protection functions.
Safety features include:
The HC1050EH48L hybrid inverter 5kw is designed according to internationally recognized standards, including:
These certifications support safer deployment in residential and distributed energy projects.
The HC1050EH48L is designed for various residential energy applications.
Applications:
Benefits:
Suitable for:
The generator compatibility function provides additional reliability.
Applications:
Multiple inverter parallel connection enables system expansion.
| Model | HC1050EH48L |
| Phase Configuration | Single Phase Input / Single Phase Output |
| Parallel Capability | Supported, up to 15 units |
| Recommended Max. PV Input Power | 10KW(5KW + 5KW) |
| Rated Output Power | 5KW |
| Dimension (DxWxH) | 320x170x440 mm |
| Net Weight (Kg) | 14.5 |
| PV INPUT (DC) | |
| Max. PV Input Voltage | 500VDC |
| PV Start-up Voltage | 90VDC |
| MPPT Voltage Range | 120VDC – 425VDC |
| MPPT Voltage @ Full Load | 295VDC – 425VDC |
| Max. PV Input Current | 18A + 18A |
| Max. PV Short-Circuit Current | 26A + 26A |
| MPPT Trackers / Strings per MPPT | 2/1 + 1 |
| AC INPUT (GRID/GENERATOR) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| AC Voltage Range | 150VAC – 290VAC |
| Grid Frequency Range | 50Hz: 45Hz-55Hz / 60Hz: 55Hz-65Hz |
| Max. AC Input Current | 40A |
| AC OUTPUT (LOAD) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| Rated Output Current | 21.8A |
| Output Frequency | 50Hz/60Hz ± 0.5Hz |
| Grid Connection Type | Single Phase ( L + N + PE ) |
| THDu | < 2% (Linear load) |
| Power Factor | > 0.99 @Rated Power (Adjustable 0.8 Leading to 0.8 Lagging) |
| Transfer Time | ≤ 10ms |
| Output Waveform | Pure sine wave |
| Overload Capability | 101%-110% @30s, >110% @10s |
| BATTERY& CHARGER | |
| Compatible Battery Types | Lead-acid / Gel or Lithium-ion |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40 – 60VDC |
| Max. Charge / Discharge Current | 110A |
| EFFICIENCY | |
| Max. Efficiency | 97.60% |
| European Efficiency | 96.50% |
| MPPT Efficiency | > 99% |
| PROTECTION | |
| Integrated Protections | Grid/Battery Over/Undervoltage Protection, Grid Over/Underfrequency Protection,
Output Short Circuit/Overload Protection, PV Reverse Polarity Alarm, Battery Overcurrent Protection (Charge/Discharge), Insulation Resistance Monitoring, Residual Current Monitoring Unit (RCMU) / Ground Fault Protection |
| COMMUNICATION & MONITORING | |
| Communication Interface | Standard: RS485/CAN; Optional: 4G/WiFi/GPRS/Bluetooth/LAN |
| Display | Touch LCD + LED Indicator |
| GENERAL | |
| Topology | Transformerless (Non-isolated) |
| Cooling Method | Intelligent Fan Cooling |
| Installation Type | Wall-mounted |
| Generator Compatibility | Supported (Generator Port / Input) |
| ENVIRONMENT | |
| Ingress Protection | IP65 |
| Noise Level | < 55dB |
| Humidity | 0~95% RH (Non-condensing) |
| Altitude | < 3000m (<2000m Recommended, Derating Above 2000m) |
| Operating Temperature | -40°C to 60°C (Power Derating Above 45°C) |
| Warranty | 5 Years standard |
| CERTIFICATES | |
| Safety & EMC Standards | IEC/EN 61000-6-1/3 , IEC/EN 61000-3-11/12, EN 62920, IEC 62109-1,