Grid Tie Inverter | 3600W | 220V/230V | Max. PV Power: 5400W | IP65
GRANKIA S3600TL 3600w anti islanding grid tie inverter for solar power is an ideal choice for users seeking a dependable, high-performance inverter that enhances solar energy efficiency while meeting strict safety requirements. Whether for home or business use, this inverter delivers optimal performance and seamless integration with the grid.
S3600TL 3600w anti islanding grid tie inverter for solar power synchronizes with the grid by matching its output frequency, voltage, and phase with the grid’s frequency, voltage, and phase.

Seamless Grid Integration
Fully compliant with grid connection standards, ensuring smooth operation and synchronization with the utility grid.
Anti-Islanding Protection
This feature prevents the inverter from feeding energy back into the grid when it is not safe to do so, such as during a power outage.
Intelligent MPPT Technology
Maximizes power output by continuously tracking the maximum power point of the solar array.
Safety Protections
Includes anti-islanding, over-voltage/current shutdown, and fault diagnostics to prevent equipment damage.
Grid-Tie Functionality
The grid tie inverter for solar can work in conjunction with the grid, allowing excess energy generated by the solar panels to be fed back into the grid and offsetting energy consumption during periods of low sunlight.
Compact and Lightweight Design
Easy to install and suitable for both indoor and outdoor applications.
The grid tie inverter for solar continuously monitors the grid’s voltage, frequency, and phase using sensors and measurement circuits.
It detects the grid frequency, which is typically 50Hz or 60Hz, depending on the region.
The inverter uses a PLL circuit to lock onto the grid’s phase. The PLL generates a reference signal that is synchronized with the grid’s phase.
This grid tie inverter regulates its output voltage to match the grid’s voltage. This is typically done using a voltage regulator circuit.
This inverter uses a synchronization algorithm to adjust its output frequency, voltage, and phase to match the grid’s parameters. This algorithm ensures that the inverter’s output is synchronized with the grid.
The inverter detects the zero-crossing point of the grid’s voltage waveform, which is the point where the voltage crosses from positive to negative or vice versa.
It synchronizes its output with the grid by generating an output waveform that is in phase with the grid’s waveform. This is done by adjusting the inverter’s output frequency, voltage, and phase to match the grid’s parameters.
| Model | S3600TL |
| INPUT (DC) | |
| Max. Input Power | 5400W |
| Max. Input Voltage | 550Vdc |
| Start Voltage/Shut Down Voltage | 75/100Vdc |
| MPPT Voltage Range | 70-500Vdc |
| Max. Input Current | 13A |
| Max. Short Circuit Current per MPPT | 17A |
| Number Of MPPT Trackers | 1 |
| String Per MPPT | 1 |
| OUTPUT(AC) | |
| Nominal Output Power | 3600W |
| Max. Output Power | 3960W |
| Max. Output Current | 16A |
| Rated Grid Frequency/Range | 50Hz (44Hz-55Hz) / 60Hz (54Hz-65Hz), auto-selection |
| Rated Grid Voltage/Range | 208Vac/220Vac/230Vac/240Vac, 180Vac-270Vac |
| Power Factor | ~1% ( 0.8 leading ~ 0.8 lagging ) |
| THDi | <1.5% ( Rated Power ) |
| EFFICIENCY | |
| Max. Conversion Efficiency | 97.80% |
| European Efficiency | 97.30% |
| MPPT Efficiency | 99.90% |
| SAFETY AND PROTECTION | |
| DC Switch | Optional |
| DC Reverse Polarity Protection | Yes |
| Anti-islanding Protection | Yes |
| Overvoltage Protection | Yes |
| AC Short Circuit Protection | Yes |
| Leakage Current Protection | Yes |
| Ground Fault Monitoring | Yes |
| Grid Monitoring | Yes |
| DC/AC Side SPD | Yes |
| COMMUNICATION | |
| Display | LCD / LED + APP |
| Communication Interface | WiFi (default) / RS485 (optional) |
| STANDARD COMPLIANCE | |
| Certificate | IEC/EN 62109-1/2, IEC/EN 61000-1/2/3 |
| GENERAL DATA | |
| Topology | Transformerless |
| Night Power Consumption | < 0.2W |
| Dimension (WxHxD) | 277x115x370mm |
| Weight | 7Kg |
| Operation Temperature | -25°C ~ +60°C |
| Relative Humidity | 0 ~ 100% |
| Operation Altitude | < 2000m without power derating |
| Noise Level | < 25dB |
| Cooling Method | Smart Cooling |
| Protection Degree | IP65 |
| Warranty | Standard 5 Years, 7/10 Years Optional |