Industrial UPS | 40KVA/32KW | 3 Phases 4 Wires + PE | 380V/400V/415V | 384VDC
GRANKIA GLT3340 backup power source 3 phase double conversion ups 40kva is suitable for inductive and capacitive loads. Built with advanced double-conversion technology and a transformer-based architecture. It ensures seamless protection against power disturbances. These disturbances include voltage fluctuations, surges, spikes, and outages.
The 3 phase double conversion ups 40kva operates effectively in unstable power environments, reducing dependency on battery usage. Online double-conversion isolates loads from grid fluctuations, ensuring uninterrupted operation. High-efficiency operation reduces energy losses and cooling demand; modular battery options minimize lifecycle cost.

Wide Input Frequency Range
Compatible with unstable or fluctuating power grids and suitable for generator operation.
Built-in Isolation Transformer
Enhances electrical safety, reduces harmonic interference, and ensures complete load protection.
Advanced Protection Systems
Safeguards against overload, short circuit, over-temperature, and battery deep discharge.
Event Logging and Self-Diagnostics
Records fault events and runs automatic system checks for predictive maintenance.
User-Friendly Interface
Equipped with an LCD display for real-time monitoring of system status, load levels, and alarms.
Multiple Communication Ports
Supports remote monitoring, management, and integration with building management systems.
Confirm input supply, available floor space, ventilation and access, and battery room requirements if external cabinets used.
Measure power factor, inrush characteristics and critical loads to size UPS and battery runtime.
Install appropriately rated circuit breakers, earthing/grounding, and isolation where required.
Battery capacity test, runtime test, transfer to bypass, and full-load performance verification.
Provide operation manual, wiring diagrams, and commissioning report.
| Model | GLT3340 |
| Capacity | 40KVA/32KW |
| INPUT | |
| Nominal Voltage | 3 Phases 4 Wires + PE, 380Vac/400Vac/415Vac |
| Acceptable Voltage Range | ± 25% |
| Frequency | 50Hz/60Hz±5% (Automatically) |
| Power Factor | ≥0.95 |
| OUTPUT | |
| Rated Voltage | 3 Phases 4 Wires + PE, 380Vac/400Vac/415Vac ± 1% |
| Rated Frequency | 50Hz/60Hz±0.05%(By Battery) |
| Harmonic Distortion | Linear load<3%, Non-linear load<5% |
| Imbalance Voltage | Balance load≤1%, Imbalance load≤3% |
| Phase Shift Angle | Balance load≤1°, Imbalance load≤2° |
| Power Factor | 0.8 |
| Overload Capacity | 110%≥300Min, 125%≥10Min, 150%≥1Min |
| Crest Factor | 3:1 |
| Wave Form | Pure Sine Wave |
| Transfer Time | 0ms |
| AC Efficiency | > 93% |
| BATTERY | |
| Battery Type | Support VRLA Battery |
| Battery Voltage | 384Vdc |
| Max. Charging Current | 0.2AxC10 |
| Charging Time(Standard) | 12hours |
| SYSTEM | |
| Display | Touch LCD Display |
| IP Protection | IP20 |
| Parallel Mode | N+1 or N+X, max. parallel up to 8 units |
| ENVIRONMENT | |
| Humidity | 0~95% (non-condensing) |
| Altitude | <1000m (with increase of 100m,it will reduce output of 1%) max. 4000m |
| Noise | 53dB~60dB(Distance 1 Meter) |
| Operating Temperature | 0℃ to 40℃ |
| Storage Temperature | -15℃ to 50℃ |
| MANAGEMENT | |
| Communication Interface | RS232/RS485 |
| Remote Signaling | Dry contact (battery low,battery discharging,bypass/fault),EPO |
| Optional SNMP | Power management from SNMP manager and web browser |
| PHYSICAL | |
| Dimension, DxWxH(mm) | 555x740x1220 |
| Net Weight (Kg) | 289 |