GLT3360 3 phase industrial low frequency online ups 60kva

Industrial UPS | 60KVA/48KW | 3 Phases 4 Wires + PE | 380V/400V/415V | 384VDC

SKU: GLT3360 Category:

GRANKIA GLT3360 3 phase industrial low frequency online ups 60kva is a high-performance uninterruptible power supply. It can provide reliable and efficient power protection for critical industrial applications. With a powerful capacity of 60 kVA, this online UPS system offers robust solutions for industries that require continuous, high-quality power.

The online UPS 60kva features intelligent battery management technology that prolongs battery life and ensures reliable operation. It includes temperature compensation, deep discharge protection, and automatic battery testing, contributing to enhanced performance and longevity.

GRANKIA GLT3360 3 phase industrial low frequency online ups 60kva

Online UPS 60kVA Features

Online Double Conversion Technology

The online ups 60kva utilizes advanced online double conversion technology. This technology ensures that connected equipment receives a stable and clean power supply. The power supply is free from voltage fluctuations, interruptions, and disturbances. This technology guarantees zero transfer time, making it ideal for sensitive industrial loads.

Built-in Isolation Transformer

Enhances electrical safety, reduces harmonic interference, and ensures complete load protection.

Wide Input Voltage Range

The online UPS supports a wide input voltage range, allowing it to accommodate various electrical environments. This feature enables the ups 60kva to function optimally even in unstable power conditions, protecting your equipment from potential damage.

Safety and Protection

The uninterruptible power supply ups is equipped with multiple safety features. These include short-circuit protection, overload protection, and surge suppression. This ensures comprehensive protection for both the UPS and connected equipment.

User-Friendly Interface

Equipped with an LCD display for real-time monitoring of system status, load levels, and alarms.

Multiple Communication Ports

Supports remote monitoring, management, and integration with building management systems.

Technical Specifications (Representative)

  • Model: GLT3360,
  • Rated power: 60 kVA / 48 kW,
  • Input: 3-phase + N (e.g., 285–475 VAC nominal, wide range),
  • Output: 3-phase + N (e.g., 380/400/415 VAC selectable),
  • Frequency: 50/60 Hz (auto-sensing or selectable),
  • THD (linear load): <3%,
  • Efficiency: up to 93%,
  • Transfer time: 0 ms (online double-conversion),
  • Battery type: VRLA/AGM standard,
  • Parallel capability: up to 8 units for redundancy,
  • Communications: RS-232, RS-485,  SNMP (optional), relay contacts.

How to Install

Preparation

  • Read the Manual: Before starting the installation, carefully read the user manual provided with the UPS. It contains important safety information and specific installation guidelines.
  • Gather Necessary Tools: Ensure you have all the necessary tools, including screwdrivers, wrenches, and any special tools mentioned in the manual.

Choose an Appropriate Location

  • Environment: Select a dry, cool, and well-ventilated area to avoid overheating. The location should be free from dust, moisture, and extreme temperatures.
  • Surface: Ensure the UPS is installed on a sturdy, level surface that can support its weight.
  • Accessibility: Leave enough space around the UPS for maintenance and monitoring. Check for clearance requirements specified in the manual.

Unpack the UPS

  • Carefully unpack the unit and check for any shipping damage. Make sure all components, including the UPS, batteries, manuals, and accessories, are included.

Connect Input Power

  • Power Source: Identify the input power source that will supply electricity to the UPS.
  • Wiring: Connect the input cables to the designated terminal block on the UPS. Follow the color coding and labeling in the manual to ensure proper connections.
  • Tighten Connections: Ensure all connections are tight to prevent arcing and connection issues.

Connect Output Power

  • Identify the equipment or load that will be powered by the UPS.
  • Connect the output cables from the UPS to the load, ensuring that the connections are secure and properly rated for the current and voltage.

Install Batteries

  • If the UPS requires external battery configuration, follow the instructions for battery installation.
  • Make sure the batteries are connected correctly, observing polarity (+/-).

Grounding

  • Properly ground the UPS according to local electrical codes. Connect the grounding wire to the designated grounding point on the UPS.

Power On the UPS

  • Ensure that all connections have been made securely.
  • Turn on the UPS using the power switch. Allow the system to perform a self-test. Verify that the LED indicators show normal operation.

Configuration and Monitoring

  • Configure any settings as required, such as alarm thresholds or network settings, if applicable.
  • Connect the UPS to a monitoring system if available, which could include software for tracking performance and notifications.

The Articles You may Like

 

Model GLT3360
Capacity 60KVA/48KW
INPUT
Nominal Voltage 3 Phases 4 Wires + PE, 380Vac/400Vac/415Vac
Acceptable Voltage Range ± 25%
Frequency 50Hz/60Hz±5% (Automatically)
Power Factor ≥0.95
OUTPUT
Rated Voltage 3 Phases 4 Wires + PE, 380Vac/400Vac/415Vac ± 1%
Rated Frequency 50Hz/60Hz±0.05%(By Battery)
Harmonic Distortion Linear load<3%, Non-linear load<5%
Imbalance Voltage Balance load≤1%, Imbalance load≤3%
Phase Shift Angle Balance load≤1°, Imbalance load≤2°
Power Factor 0.8
Overload Capacity 110%≥300Min, 125%≥10Min, 150%≥1Min
Crest Factor 3:1
Wave Form Pure Sine Wave
Transfer Time 0ms
AC Efficiency > 93%
BATTERY
Battery Type Support VRLA Battery
Battery Voltage 384Vdc
Max. Charging Current 0.2AxC10
Charging Time(Standard) 12hours
SYSTEM
Display Touch LCD Display
IP Protection IP20
Parallel Mode N+1 or N+X, max. parallel up to 8 units
ENVIRONMENT
Humidity 0~95% (non-condensing)
Altitude <1000m (with increase of 100m,it will reduce output of 1%) max. 4000m
Noise 53dB~62dB(Distance 1 Meter)
Operating Temperature 0℃ to 40℃
Storage Temperature -15℃ to 50℃
MANAGEMENT
Communication Interface RS232/RS485
Remote Signaling Dry contact (battery low,battery discharging,bypass/fault),EPO
Optional SNMP Power management from SNMP manager and web browser
PHYSICAL
Dimension, DxWxH(mm) 555x740x1220
Net Weight (Kg) 363
GDPR GRANKIA
Your Privacy

GRANKIA stores and retrieves information on your browser through cookies. This information helps ensure the website functions properly and may relate to you, your preferences, or your device. Additionally, we utilize cookies to enhance your browsing experience with personalized content. It's important to note that blocking certain types of cookies could impact your website experience and the services we offer. For a more comprehensive overview of the cookies we use, please consult our Privacy Policy.