IP65 Hybrid Solar Inverter | 6000W | 2MPPTs: 18A + 18A | 48VDC | Max. Charging: 120A
GRANKIA HC1060EH48L is a 6kW single phase inverter designed for residential solar backup systems. It is featuring 12kW PV input capability, dual MPPT tracking, 97.6% maximum efficiency, IP65 outdoor protection, 48V battery compatibility, and ≤10ms backup transfer. It delivers reliable solar conversion, battery storage management, and uninterrupted home power.
A single phase inverter converts DC electricity from solar panels or batteries into AC electricity for household appliances.
The HC1060EH48L single phase inverter is a hybrid energy conversion unit for residential solar systems, backup power applications, and small commercial energy storage projects.

The inverter has a rated output power of 6kW. It integrates solar PV generation, battery charging, grid interaction, and emergency backup functions into one wall-mounted unit.
It supports:
The HC1060EH48L single phase inverter delivers power output for homes requiring energy independence, grid backup, and higher solar self-consumption.
The enclosure meets IP65 rating: dust-tight and protected against low-pressure water jets from any direction.
You do not need an indoor utility room or protective cabinet.
Installers can mount this single phase inverter on an exterior wall, garage, or carport. This reduces wiring runs and installation labor by up to 30% in typical residential layouts.
The inverter delivers 6000W continuous rated power. It has a surge capacity that supports motor-start loads such as pumps and air conditioners.
The inverter handles high inrush current without tripping. Undersized inverters fault on compressor startup.
This single phase inverter covers loads for most 3–5 bedroom households on one unit. You avoid the cost of paralleling multiple smaller inverters.
The HC1060EH48L IP65 solar inverter 6000w uses an independent dual MPPT structure.
Each MPPT channel tracks the maximum power point of PV strings.
This improves energy harvesting when solar panels experience:
| Solar Input Parameter | Technical Value |
| Maximum PV Voltage | 500VDC |
| PV Start-up Voltage | 90VDC |
| MPPT Voltage Range | 120VDC – 425VDC |
| Full Load MPPT Range | 350VDC – 425VDC |
| MPPT Trackers | 2 |
| Strings per MPPT | 1 + 1 |
| Maximum PV Current | 18A + 18A |
| PV Short Circuit Current | 26A + 26A |
The dual MPPT design increases solar generation performance compared with single MPPT systems.
For residential users, this means:
This makes the HC1060EH48L an ideal 6kW hybrid inverter for home solar battery backup systems.

The HC1060EH48L outdoor-rated solar inverter serves applications requiring backup electricity.
The transfer time is ≤10ms. The inverter switches to battery backup mode when grid power fails.
Typical backup applications include:
The pure sine wave output ensures compatibility with sensitive electronic equipment.
AC Output Performance
| AC Output Parameter | Specification |
| Rated Power | 6000W |
| Output Voltage | 220/230/240VAC |
| Rated Current | 26.1A |
| Output Frequency | 50Hz / 60Hz |
| Waveform | Pure Sine Wave |
| Power Factor | >0.99 |
| THDu | <2% |
| Transfer Time | ≤10ms |
The HC1060EH48L uses a 48V battery architecture for residential energy storage applications.
Compared with high-voltage battery systems, 48V batteries offer several practical advantages:
The inverter supports multiple battery technologies, including:
This flexibility allows installers to select battery solutions based on system capacity, budget, and application requirements.
| Battery Parameter | Specification |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40-60VDC |
| Maximum Charge Current | 120A |
| Maximum Discharge Current | 120A |
| Compatible Battery Type | Lithium / Lead-acid / Gel |
| Battery Communication | CAN / RS485 |
The high 120A charging and discharging capability enables efficient energy management.
During daytime:
During nighttime or grid failure:
This operation improves solar self-consumption and reduces dependence on utility electricity.
For users searching for a 48V hybrid inverter with lithium battery compatibility, the HC1060EH48L provides a flexible and scalable energy storage platform.
The HC1060EH48L IP65 single phase inverter supports both grid connection and generator input, providing multiple energy supply options.
The hybrid solar inverter can automatically manage:
This makes it suitable for areas with:
The generator compatibility function provides an additional backup energy source.
When solar and battery capacity are insufficient, the system can automatically utilize generator power to maintain stable electricity supply.
This feature is particularly valuable for:
Residential energy requirements can increase over time.
The HC1060EH48L supports parallel connection of up to 15 units, allowing flexible system expansion.
A single inverter can provide:
Multiple units can increase:
| System Configuration | Total Output Capacity |
| 1 × HC1060EH48L | 6kW |
| 5 × HC1060EH48L | 30kW |
| 10 × HC1060EH48L | 60kW |
| 15 × HC1060EH48L | 90kW |

The parallel design reduces the need for replacing existing equipment when energy demand grows.
It provides an economical upgrade path for:
| Parameter | Specification |
| Model | HC1060EH48L |
| Rated Output Power | 6kW |
| Phase Configuration | Single Phase Input / Single Phase Output |
| Recommended Maximum PV Input | 12kW |
| AC Output Voltage | 220V/230V @50Hz/60Hz |
| Battery Voltage | 48VDC |
| Battery Type | Lead-acid / Gel / Lithium-ion |
| Maximum Efficiency | 97.60% |
| MPPT Efficiency | >99% |
| Protection Rating | IP65 |
| Transfer Time | ≤10ms |
| Parallel Capability | Up to 15 Units |
| Installation | Wall-mounted |
| Cooling Method | Intelligent Fan Cooling |
| Operating Temperature Range | -25°C to 60°C |
| Criterion | HC1060EH48L (IP65) | Standard Indoor Inverter (IP20) |
| Installation Location | Outdoor or indoor | Indoor only |
| Enclosure Protection | Dust-tight, water-jet resistant | Basic dust protection only |
| Extra Housing Required | No | Often yes, for outdoor use |
| Backup Switchover Speed | < 10 ms | 10–20 ms typical |
| Suitable for Coastal/Humid Climates | Yes | Limited, corrosion risk |

Solar PV energy supplies household loads. Excess PV energy beyond load demand charges the 48V battery bank. The system does not export to the utility grid.
When solar power is unavailable or insufficient, the inverter discharges the battery to supply household loads. If the battery reaches its preset depth of discharge (DoD), utility grid power supplies the load demand.
The system maximizes solar self-consumption and prevents energy backflow into the utility grid.
The inverter synchronizes with utility frequency and exports surplus solar power, functioning as a standard grid-interactive single phase inverter.
Runs independently from battery and PV input, suitable for remote sites without utility connection.
Combines both: prioritizes solar and battery use during the day, switches to grid or battery seamlessly at night or during outages.
Safety is critical for residential solar energy systems.
The HC1060EH48L integrates multiple hardware and software protection functions.
These include:
The inverter complies with international safety and EMC requirements, including:
These standards ensure reliable operation in global solar markets.
The HC1060EH48L supports various solar energy applications.
For homeowners, the inverter provides:
In remote locations, the system can operate with:
It provides stable electricity without relying completely on utility infrastructure.
The parallel function allows expansion for:
| Model | HC1060EH48L |
| Phase Configuration | Single Phase Input / Single Phase Output |
| Parallel Capability | Supported, up to 15 units |
| Recommended Max. PV Input Power | 12KW(6KW + 6KW) |
| Rated Output Power | 6KW |
| Dimension (DxWxH) | 320x170x440 mm |
| Net Weight (Kg) | 15.0 |
| PV INPUT (DC) | |
| Max. PV Input Voltage | 500VDC |
| PV Start-up Voltage | 90VDC |
| MPPT Voltage Range | 120VDC – 425VDC |
| MPPT Voltage @ Full Load | 350VDC – 425VDC |
| Max. PV Input Current | 18A + 18A |
| Max. PV Short-Circuit Current | 26A + 26A |
| MPPT Trackers / Strings per MPPT | 2/1 + 1 |
| AC INPUT (GRID/GENERATOR) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| AC Voltage Range | 150VAC – 290VAC |
| Grid Frequency Range | 50Hz: 45Hz-55Hz / 60Hz: 55Hz-65Hz |
| Max. AC Input Current | 40A |
| AC OUTPUT (LOAD) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| Rated Output Current | 26.1A |
| Output Frequency | 50Hz/60Hz ± 0.5Hz |
| Grid Connection Type | Single Phase ( L + N + PE ) |
| THDu | < 2% (Linear load) |
| Power Factor | > 0.99 @Rated Power (Adjustable 0.8 Leading to 0.8 Lagging) |
| Transfer Time | ≤ 10ms |
| Output Waveform | Pure sine wave |
| Overload Capability | 101%-110% @30s, >110% @10s |
| BATTERY& CHARGER | |
| Compatible Battery Types | Lead-acid / Gel or Lithium-ion |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40 – 60VDC |
| Max. Charge / Discharge Current | 120A |
| EFFICIENCY | |
| Max. Efficiency | 97.60% |
| European Efficiency | 96.50% |
| MPPT Efficiency | > 99% |
| PROTECTION | |
| Integrated Protections | Grid/Battery Over/Undervoltage Protection, Grid Over/Underfrequency Protection,
Output Short Circuit/Overload Protection, PV Reverse Polarity Alarm, Battery Overcurrent Protection (Charge/Discharge), Insulation Resistance Monitoring, Residual Current Monitoring Unit (RCMU) / Ground Fault Protection |
| COMMUNICATION & MONITORING | |
| Communication Interface | Standard: RS485/CAN; Optional: 4G/WiFi/GPRS/Bluetooth/LAN |
| Display | Touch LCD + LED Indicator |
| GENERAL | |
| Topology | Transformerless (Non-isolated) |
| Cooling Method | Intelligent Fan Cooling |
| Installation Type | Wall-mounted |
| Generator Compatibility | Supported (Generator Port / Input) |
| ENVIRONMENT | |
| Ingress Protection | IP65 |
| Noise Level | < 55dB |
| Humidity | 0~95% RH (Non-condensing) |
| Altitude | < 3000m (<2000m Recommended, Derating Above 2000m) |
| Operating Temperature | -40°C to 60°C (Power Derating Above 45°C) |
| Warranty | 5 Years standard |
| CERTIFICATES | |
| Safety & EMC Standards | IEC/EN 61000-6-1/3 , IEC/EN 61000-3-11/12, EN 62920, IEC 62109-1,
IEC 62109-2, IEC 62321 |