IP65 Hybrid Solar Inverter | 4000W | 2MPPTs: 18A + 18A | 48VDC | Max. Charging: 100A
GRANKIA HC1040EH48L inverter is a 4kW solar power inverter unit. It has an IP65 rated casing, dual MPPT solar power inverter tracking channels for 8kW PV oversized input, and 48V battery connection. It operates at 97.6% efficiency with a ≤10ms UPS transfer time. This inverter provides solar power inverter energy management under extreme outdoor conditions.
The HC1040EH48L 4kW IP65 solar power inverter is a hybrid energy conversion solution for modern residential solar systems. It combines solar energy harvesting, battery charging, grid interaction, and backup power management in one wall-mounted unit.
With a recommended maximum PV input power of 8kW (4kW + 4kW), dual MPPT tracking technology, and compatibility with 48V lead-acid, gel, and lithium batteries, it increases solar utilization and supplies household electricity.
The IP65 solar power inverter supports 220V/230V/240V single-phase applications. It is suitable for homes, villas, remote houses, and small off-grid energy systems.
Residential energy users require more than basic solar conversion.
They need:
The HC1040EH48L addresses these requirements through an integrated hybrid architecture.
It works as a:
This makes it an ideal 48V hybrid solar inverter for home energy storage applications.

| Model | HC1040EH48L |
| Rated Output Power | 4kW |
| PV Input Power | Max. 8kW (4kW + 4kW) |
| Battery Voltage | 48VDC |
| Battery Voltage Range | 40-60VDC |
| Phase Configuration | Single Phase Input / Single Phase Output |
| PV Maximum Voltage | 500VDC |
| MPPT Voltage Range | 120VDC-425VDC |
| MPPT Trackers | 2 MPPT |
| Maximum Efficiency | 97.60% |
| MPPT Efficiency | >99% |
| Protection Rating | IP65 |
| Installation | Wall-mounted |
| Weight | 14kg |
| Warranty | 5 Years |
The HC1040EH48L solar power inverter has two independent MPPT channels. They support up to 8kW total PV input power. This inverter accepts a PV voltage of 500VDC maximum, with a 120VDC to 425VDC MPPT range and 18A input current per tracker in this solar power inverter configuration.
This design improves energy generation when solar panels have different:
Compared with single MPPT systems, dual MPPT architecture provides more PV system design options.
| Feature | Traditional Solar Inverter | HC1040EH48L |
| MPPT Quantity | Usually 1 | 2 MPPT |
| PV Input Power | Limited matching flexibility | Up to 8kW |
| Panel Orientation | Less flexible | Multiple roof directions |
| Partial Shading Performance | Average | Improved |
| Solar Utilization | Standard | Optimized |
Homeowners harvest more daily energy, increasing solar power inverter payback and securing backup power.
The inverter has an IP65 ingress protection shell. It operates from -40°C to +60°C. A fan cooling system adjusts air circulation based on internal thermal demand.
This IP65 rating permits outdoor installation of this solar power inverter. It protects solar power inverter power electronics from dust, rain, and humidity without secondary protective cabinets.
The design saves indoor space, keeps operational noise below 55dB, and removes additional enclosure installation costs for the inverter.

When solar power generation exceeds the load demand and battery charging capacity, the excess electricity can flow back to the grid.
If local power regulations or utility agreements prohibit exporting power to the grid, the inverter supports external anti-backflow control.
This feature allows you to limit or completely block power feedback into the grid depending on your site configuration.
The HC1040EH48L supports multiple battery technologies.
Compatible batteries include:
The system operates with:
This makes it suitable for:
The HC1040EH48L solar power inverter delivers stable AC output with:
It safely powers household equipment including:
The hybrid solar inverter supports adjustable power factor operation from: 0.8 leading to 0.8 lagging
This improves compatibility with different electrical loads.
By paralleling up to 15 units, the system can scale from a single unit up to a maximum total output capacity of 60kW.
Inverter models designated with a “P” suffix are equipped with parallel communication hardware. You can connect up to 15 units in parallel to scale total output power and battery capacity for larger residential or commercial installations. (Pm – Master; P – Slave).
Parallel-enabled units synchronize AC output frequency, voltage phase, and real-time load distribution via dedicated communication lines (RS485/CAN).
All connected units coordinate PV input power, charge/discharge cycles, and grid feed-in/backup modes seamlessly across the shared AC bus.

For areas with unstable grid supply, the HC1040EH48L provides reliable backup performance.
Key functions include:
This allows continuous power supply for essential household loads.
Typical applications include:
Daytime: Solar power generation prioritizes powering local loads first. Any excess PV power generated beyond load demand is exported (sold) back to the utility grid.
Nighttime / Low Solar: When solar generation is unavailable, the system discharges the battery to supply connected loads. If battery energy is insufficient, the grid provides backup power

The HC1040EH48L IP65 solar power inverter integrates multiple protection functions.
Safety features include:
The design complies with international safety and EMC requirements:
The HC1040EH48L is designed for various residential energy applications.
Ideal for:
Suitable for:
Provides emergency electricity for:
| Model | HC1040EH48L |
| Phase Configuration | Single Phase Input / Single Phase Output |
| Parallel Capability | Supported, up to 15 units |
| Recommended Max. PV Input Power | 8KW(4KW + 4KW) |
| Rated Output Power | 4KW |
| Dimension (DxWxH) | 320x170x440 mm |
| Net Weight (Kg) | 14.0 |
| PV INPUT (DC) | |
| Max. PV Input Voltage | 500VDC |
| PV Start-up Voltage | 90VDC |
| MPPT Voltage Range | 120VDC – 425VDC |
| MPPT Voltage @ Full Load | 235VDC – 425VDC |
| Max. PV Input Current | 18A + 18A |
| Max. PV Short-Circuit Current | 26A + 26A |
| MPPT Trackers / Strings per MPPT | 2/1 + 1 |
| AC INPUT (GRID/GENERATOR) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| AC Voltage Range | 150VAC – 290VAC |
| Grid Frequency Range | 50Hz: 45Hz-55Hz / 60Hz: 55Hz-65Hz |
| Max. AC Input Current | 30A |
| AC OUTPUT (LOAD) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| Rated Output Current | 17.4A |
| Output Frequency | 50Hz/60Hz ± 0.5Hz |
| Grid Connection Type | Single Phase ( L + N + PE ) |
| THDu | < 2% (Linear load) |
| Power Factor | > 0.99 @Rated Power (Adjustable 0.8 Leading to 0.8 Lagging) |
| Transfer Time | ≤ 10ms |
| Output Waveform | Pure sine wave |
| Overload Capability | 101%-110% @30s, >110% @10s |
| BATTERY& CHARGER | |
| Compatible Battery Types | Lead-acid / Gel or Lithium-ion |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40 – 60VDC |
| Max. Charge / Discharge Current | 100A |
| EFFICIENCY | |
| Max. Efficiency | 97.60% |
| European Efficiency | 96.50% |
| MPPT Efficiency | > 99% |
| PROTECTION | |
| Integrated Protections | Grid/Battery Over/Undervoltage Protection, Grid Over/Underfrequency Protection, Output Short Circuit/Overload Protection, PV Reverse Polarity Alarm, Battery Overcurrent Protection (Charge/Discharge), Insulation Resistance Monitoring, Residual Current Monitoring Unit (RCMU) / Ground Fault Protection |
| COMMUNICATION & MONITORING | |
| Communication Interface | Standard: RS485/CAN; Optional: 4G/WiFi/GPRS/Bluetooth/LAN |
| Display | Touch LCD + LED Indicator |
| GENERAL | |
| Topology | Transformerless (Non-isolated) |
| Cooling Method | Intelligent Fan Cooling |
| Installation Type | Wall-mounted |
| Generator Compatibility | Supported (Generator Port / Input) |
| ENVIRONMENT | |
| Ingress Protection | IP65 |
| Noise Level | < 55dB |
| Humidity | 0~95% RH (Non-condensing) |
| Altitude | < 3000m (<2000m Recommended, Derating Above 2000m) |
| Operating Temperature | -40°C to 60°C (Power Derating Above 45°C) |
| Warranty | 5 Years standard |
| CERTIFICATES | |
| Safety & EMC Standards | IEC/EN 61000-6-1/3 , IEC/EN 61000-3-11/12, EN 62920, IEC 62109-1, IEC 62109-2, IEC 62321 |