Split Phase Solar Inverter | 11400W | 120V/240V 60Hz | 48VDC | Max. Charging: 200A
GRANKIA HS2114UH48L dual mppt 11.4kw 48v split phase hybrid inverter can work for modern residential and light commercial solar energy systems.
The dual MPPT 11.4 kW 48V split phase hybrid inverter manages solar generation efficiently. It also manages battery storage and grid interaction. This 48V split phase hybrid inverter does this with high efficiency and stability. It supports both on‑grid and off‑grid operation, making it suitable for backup power, self‑consumption optimization, and small off‑grid projects.
The 48V split phase hybrid inverter serves the North American market. It features a split-phase 120/240V AC output. This enables seamless integration with standard household appliances and electrical panels. Its advanced dual MPPT architecture allows independent optimization of two separate solar array strings. The hybrid inverter maximizes energy harvest even under partial shading. It also performs well with varying panel orientations.

High-Efficiency Pure Sine Wave Output
Delivers clean, stable 120V/240V split-phase AC power with pure sine wave waveform, safely powering sensitive electronics, motors, and heavy appliances.
Dual MPPT Solar Charge Controllers
Two high-efficiency MPPT trackers have a wide PV input voltage range. This range is typically 90–450Vdc or similar. These trackers allow optimal harvesting from two differently oriented or shaded roof arrays. Maximum PV input power up to 15kW (7500W + 7500W), maximizing solar production year-round.
48V Low-Voltage Battery System
Compatible with most popular 48V battery types:
Lithium-ion (LiFePO4 with BMS communication)
AGM / Gel / Flooded lead-acid
Supports closed-loop communication with leading brands (Pylontech, etc.) for precise SOC management and longer battery life.
Advanced Hybrid Functionality
Grid-interactive (sell back excess solar power when allowed)
Automatic generator start (dry contact for 2-wire start)
Time-of-use scheduling & programmable charge/discharge periods
Built-in smart load management port (for non-essential loads)
Unlimited Load Capacity with Smart Adaptation
Features dynamic over-power adaptation. It handles temporary surges and high starting loads. This ensures the system can support demanding appliances without tripping.
Smart Energy Management
Supports time-of-use scheduling, load shedding, and optional remote monitoring via Wi-Fi/RS485.

| No. | Parts | Description |
| 1 | Solar Inverter | Split-phase solar inverter. |
| 2 | Battery Bank | Select the appropriate battery model according to the inverter–battery compatibility list. |
| 3 | PV String | A PV string consists of multiple photovoltaic modules connected in series. |
| 4 | Battery Breaker | Users should prepare a 2P DC circuit breaker. |
| 5 | AC Breaker | The AC breaker specifications for the LOAD and GRID must be the same for a given inverter model. The AC breaker should be provided by the end user. |
| 6 | SPDT Switch | To ensure the load can be powered by the grid during inverter maintenance, install an SPDT switch. |
| 7 | Generator | The generator’s maximum output power must be equal to or greater than the inverter’s rated power. |


| 1.LED Indicator | 2.LCD Display | 3.AC Input Breaker | 4.Label |
| 5.PV Input Switch | 6.Ground(PE) | 7.Power On/Off | 8.WiFi/GPRS (Option) |
| 9.AC Input Terminal | 10.Second Output / Generator Input Terminal | 11.Main Output Terminal | 12.COM Communication Port |
| 13.BMS Communication Port | 14.Dry Contact | 15.Battery Terminal | 16.PV Input Terminal (PV1/PV2) |

Solar panels generate power and feed it into the inverter.
Priority of power usage:
Solar power supplies household loads first.
Excess solar power charges the batteries.
Remaining energy is exported to the grid (feed-in).
Surplus energy can be exported to the grid (if enabled).
Solar input is unavailable.
The inverter supplies loads using:
The grid can also charge the batteries according to settings (e.g. time-of-use mode).
The utility grid is disconnected.
The inverter automatically switches to backup mode.
Loads are powered by:
Solar panels (if available), and
Batteries.
Critical loads continue to run without interruption, ensuring power reliability during outages.

During high electricity price hours, the inverter prioritizes self-consumption.
Solar energy and battery power are used first to supply household loads.
The battery discharges to reduce or avoid using expensive grid electricity.
If enabled, excess energy can be exported to the grid.
This mode helps users lower electricity bills during peak hours.
During low electricity price hours, the all in one split phase inverter focuses on charging the battery.
The battery can be charged by:
Solar power (priority source), and
Grid power when solar is insufficient.
Loads are still powered normally while charging takes place.
This ensures that the system fully charges the battery and gets it ready for the next peak period.
This 48v split phase hybrid inverter supports multiple operating modes in one unit: grid‑tie, off‑grid, and hybrid with battery backup. This can prioritize solar power. The inverter charges batteries when excess energy is available. It automatically draws from batteries during grid outages to keep critical loads running.
Typical working scenarios include:
Backup mode, where batteries and PV maintain essential loads during power failures.
Time‑of‑use optimization, charging the battery when tariffs are low and discharging during peak pricing (depending on local policy and configuration).
| Model | HS2114UH48L |
| Rated Power | 11400W |
| Parallel Capability | No |
| AC / GENERATOR INPUT | |
| Nominal Voltage | 120Vac – 240Vac |
| Voltage Range | 90Vac-1400Vac(L-N), 180Vac-280Vac(L-L) |
| Frequency Range | 50Hz: 47-55Hz / 60Hz: 57-65Hz, ±0.3Hz |
| AC OUTPUT | |
| Nominal Voltage | 120Vac / 240Vac |
| Frequency | 50Hz / 60Hz ±0.3Hz(Auto) |
| Rated Current | 47.5A |
| Max. Efficiency | 92.00% |
| Transfer Time | 10ms |
| Waveform | Pure Sine Wave |
| BATTERY | |
| Battery Type | Lead-acid / Gel / LiFePO4 |
| Battery Rated Voltage | 48VDC |
| Battery Voltage Range | 40-60VDC |
| Default Charging Current | 60A |
| CHARGER | |
| Max. PV Array Power | 7500W + 7500W |
| MPPT Range @ Operating Voltage | 90-450VDC |
| Max. PV Array Open Circuit Voltage | 500VDC |
| Max. Solar Charge Current | 200A |
| AC Charge Current | 120A |
| Maximum Charge Current | 200A |
| ENVIRONMENT | |
| Installation Method | Wall-mounted |
| Humidity | 5%~95%(No condensation) |
| Operation Temperature | -10℃ ~ 55℃ |
| Storage Temperature | -20℃ ~ 60℃ |
| Altitude | ≤2000m** |
| INTERFACE | |
| Communication | RS485/CAN, Optional Wi-Fi/GPRS |
| Display | LCD + LED |
| MECHANICAL | |
| Dimension, WxDxH (mm) | 465x140x620 |
| Weight (Kg) | 28.0 |
| CERTIFICATIONS | |
| Certificate | FCC, UL |
| Standard | FCC47 CFR Port 15, UL1741, TSCA, CA65 |