GIR4K-48 3U single phase 48v rack mount power inverter 4000w

Power Inverter | 4000W | 48VDC | 3U | Rack Mounted

SKU: GIR4K-48 Category:

GRANKIA GIR4K-48 3U single phase 48v rack mount power inverter 4000w offers true sine-wave output suitable for sensitive electronics.  The 48v rack mount power inverter 4000w is a heavy-duty, industrial-grade power solution. It’s designed for seamless integration into standard 19-inch rack systems.

This rack mount power inverter is engineered for reliability and high efficiency. It converts 48V DC battery power into stable, clean AC power. This makes it the ideal choice for telecommunications, data centers, and critical emergency backup systems.

The 48v rack mount power inverter stands out for its stability and ease of installation. Whether you are managing a remote telecom site or a sophisticated server room, this inverter offers reliability. This reliability is of the “set-and-forget” type, essential for mission-critical operations.

GRANKIA GIR4K-48 3U single phase 48v rack mount power inverter 4000w

Rack Mount Power Inverter Features

Built-in Toroidal Transformer

Enhances conversion efficiency, reduces electrical noise, and ensures a stable, low-distortion sine wave output.

Peak/surge capacity

Up to 12000W for short-duration motor starts and high inrush loads.

48V DC input

Direct connection to common telecom and battery backup systems (lead-acid, AGM, gel, or Li-ion banks sized for 48V).

Rack-mount 3U form factor

3U rack-mount chassis for dense equipment racks and cabinets.

Protections

Overload, short-circuit, over/under-voltage, over-temperature, reverse polarity, and ground-fault protection to protect both inverter and connected loads.

Cooling

Front-to-back forced-air cooling with smart fan control for temperature-dependent speed.

 

Technical Specifications (Representative)

  • Model: GIR4K-48,
  • Rated power: 4000W,
  • AC Input: 110V/120V or 220V/230V/240V,
  • AC Output: 110V/120V or 220V/230V/240V,
  • Frequency: 50/60 Hz (auto-sensing or selectable),
  • DC Input: 48VDC,
  • Transfer time: <8 ms,
  • Battery type: VRLA/AGM/LiFePO4,
  • Wave Form: Pure Sine Wave,
  • Communications: RS-232,
  • Dimension: 483x420x132mm [3U].

Product Overview

GRANKIA rack mounted dc to ac inverter diagram

GRANKIA Rack mount power inverter battery charging adjustable

GRANKIA pure sine wave rack mount dc ac power inverter rear view

Fault Code List

Code Description
E01 Power amplifier over current
E02 Output short circuit protection
E03 Overload protection
E04 Over temperature protection
E05 Battery over voltage protection
E06 Low battery voltage protection
E07 Phase reverse protection
E08 Low output voltage protection
E09 Date of manufacture does not match
E10 Battery power down, voltage drop

Applications

  • Data centers and server racks requiring compact, high-power DC-to-AC conversion.
  • Telecom base stations and network shelters with 48V battery banks.
  • Edge computing, industrial automation, and control rooms.
  • Backup power for critical loads, UPS systems, and inverter-based power distribution.
  • Renewable energy systems where 48V battery storage is used.

Installation

  • Mount unit in a 19″ rack with specified front/rear clearances (min. 50 mm rear, 100 mm top recommended).
  • Install appropriate battery cabling: use battery‑rated, low‑impedance cables sized for max DC current; keep cable runs short.
  • Fit DC protection: DC fuse or breaker sized per inverter input current, installed close to battery positive terminal.
  • Connect AC output to distribution panel via appropriately rated breakers and wiring. Ensure neutral and earth bonding per local code.
  • Configure output voltage/frequency and protection thresholds via local display or remote interface.
  • Enable/verify communications and logging; integrate into monitoring system.
  • Perform no‑load and stepped-load commissioning tests; verify thermal behavior and alarm responses.
  • Document serial numbers, firmware versions, and commissioning measurements.

 

The Articles You may Like

Model GIR4K-48
Capacity 4000W
INPUT
Nominal Voltage 110V/120V or 220V/230V/240V
Acceptable Voltage Range +/-25%
Frequency 50Hz/60Hz ±2.5Hz (Auto Sensing)
OUTPUT
Rated Voltage 110V/120V or 220V/230V/240V
Voltage Regulation AC Mode: +/-10%; Battery Mode: +/-5%
Rated Frequency 50Hz/60Hz ±0.5Hz (Auto Sensing)
Instantaneous Power 12000W
Harmonic Distortion Linear load <3%; Non-linear load <5%
Overload Capacity >110% for 60s; >120% for 10s
Crest Factor 3:1
Wave Form Pure Sine Wave
Transfer Time < 8ms
EFFICIENCY
Battery Efficiency ≥ 85%
AC Efficiency ≥ 93%
BATTERY
Battery Type AGM / GEL / LiFePO₄ / User Defined
Rate Voltage 48VDC
Float Charge Voltage 54.4VDC
High Voltage Protection 66.0VDC
Low Voltage Protection 42.0VDC
Charging Current 0-40A
Charging Algorithm Bulk / Absorption / Float
SYSTEM
Standby Consumption 50W
Mounting Type Rack-mount
Ingress Protection IP20
Cooling Method Intelligent Fan Cooling
Display LCD + LED Indicators
Protection Overload, Short Circuit, Reverse Polarity, Over/Low Voltage, Overheat
Communication Interface RS232, RS485 / SNMP / MODBUS (optional)
ENVIRONMENT
Humidity 15~95% (non-condensing)
Altitude ≤1000m (with increase of 100m,it will reduce output of 1%) max. 3000m
Operating Temperature 0℃ to 40℃
Storage Temperature -15℃ to 50℃
PHYSICAL
Dimension, DxWxH(mm) 483x420x132[3U]
Weight (Kg) 24
GDPR GRANKIA
Your Privacy

GRANKIA stores and retrieves information on your browser through cookies. This information helps ensure the website functions properly and may relate to you, your preferences, or your device. Additionally, we utilize cookies to enhance your browsing experience with personalized content. It's important to note that blocking certain types of cookies could impact your website experience and the services we offer. For a more comprehensive overview of the cookies we use, please consult our Privacy Policy.