IP65 Hybrid Solar Inverter | 6600W | 2MPPTs: 18A + 18A | 48VDC | Max. Charging: 120A
GRANKIA HC1066EH48L is a 6.6kW single phase hybrid inverter solar solution with dual MPPT inputs (13.2kW PV Max), 48V battery architecture, 120A charge/discharge current, and ≤10ms transfer time. It supports up to 15 parallel units, IP65 protection, and IEC safety compliance. It delivers off-grid operation and grid-tied energy management for residential use.
The HC1066EH48L hybrid inverter solar system serves residential energy storage, backup power, and small commercial solar applications.
It combines:
in a single compact wall-mounted unit.
Rated output power: 6.6kW. The inverter supports high-demand household loads and maintains power quality.
The transformerless topology reduces losses.
The MPPT algorithm extracts solar power.
The 48V battery architecture works with lithium-ion, gel, and lead-acid batteries.

Modern energy users require more than basic solar conversion.
They need:
The HC1066EH48L hybrid inverter solar addresses these requirements through intelligent control technology and robust electrical design.
| Feature | Specification | User Value |
| Rated Output Power | 6.6kW | Supports high-power household appliances |
| Battery Voltage | 48VDC | Compatible with mainstream storage batteries |
| Maximum PV Input Power | 13.2kW | Allows oversized solar array design |
| MPPT Trackers | Dual MPPT | Better solar generation under shading conditions |
| Maximum Efficiency | 97.60% | Reduces energy losses |
| Protection Level | IP65 | Suitable for indoor and outdoor installation |
| Parallel Capability | Up to 15 units | Expandable power capacity |
| Transfer Time | ≤10ms | Reliable backup switching |
The HC1066EH48L single phase hybrid inverter solar delivers:
The inverter provides stable AC power suitable for sensitive electronic equipment.
The output THDu is:
<2% under linear load
Power factor reaches:
>0.99 at rated power
(adjustable from 0.8 leading to 0.8 lagging)
Users can operate:
with reliable electricity quality.
The inverter supports:
PV input configuration:
| Parameter | Specification |
| MPPT Number | 2 |
| Strings per MPPT | 1 + 1 |
| Maximum PV Current | 18A + 18A |
| Maximum PV Short Circuit Current | 26A + 26A |
| Full Load MPPT Voltage | 370VDC-425VDC |
Dual MPPT technology allows two independent solar strings to operate separately.
This improves energy harvesting when:
Compared with single MPPT systems, dual MPPT designs provide better PV system flexibility.
The system can generate more usable solar energy throughout the day.
For homeowners, this means:
The HC1066EH48L is therefore suitable as a 6.6kW solar hybrid inverter for home energy storage applications.
The HC1066EH48L is designed as a flexible hybrid inverter solar platform that supports multiple energy operation modes.
It intelligently coordinates:
The built-in energy management system automatically prioritizes available energy sources according to system conditions.
The HC1066EH48L supports parallel connection.
Maximum parallel quantity: Up to 15 units
Multiple inverter units can operate together to increase system capacity.

A single unit provides:
6.6kW output power
A 15-unit parallel system can theoretically reach:
99kW class power capacity
This scalability makes the inverter suitable for:
The HC1066EH48L supports generator integration.
Compatible with:
Generator input provides additional energy security when:
The inverter manages multiple power sources automatically.
Users in remote or unstable grid areas can build a more reliable energy system.
Typical markets include:
Sealed fan-assisted cooling design rated for demanding indoor and outdoor deployment environments.

The HC1066EH48L integrates comprehensive protection functions.
| Protection Function | Technical Purpose |
|---|---|
| Battery Over/Under Voltage Protection | Protects battery safety |
| Battery Overcurrent Protection | Prevents excessive charging/discharging |
| PV Reverse Polarity Alarm | Protects PV input circuit |
| Grid Over/Under Voltage Protection | Maintains grid safety |
| Grid Over/Under Frequency Protection | Ensures stable operation |
| Output Short Circuit Protection | Protects connected loads |
| Overload Protection | Prevents inverter damage |
| Insulation Resistance Monitoring | Improves electrical safety |
| RCMU / Ground Fault Protection | Enhances user protection |
The HC1066EH48L is designed according to recognized international standards.
Certified standards include:
| Parameter | Specification |
| Solar Input (DC) | |
| Max. Recommended PV Power | 13.2 kW (6.6 kW / 6.6 kW) |
| Max. PV Input Voltage | 500 VDC |
| MPPT Voltage Range | 120 VDC – 425 VDC |
| Max. Input Current | 18A + 18A |
| AC Output (Load/Grid) | |
| Rated Output Power | 6.6 kW / 6.6 kVA |
| Nominal AC Voltage | 220VAC / 230VAC / 240VAC |
| Rated Output Current | 28.7 A |
| Peak Transfer Time | ≤ 10 ms |
| Battery Storage | |
| Battery Nominal Voltage | 48 VDC (40 – 60 VDC range) |
| Max. Charge/Discharge Current | 120 A |
| Battery Chemistry Support | Lithium-ion / Lead-acid / Gel |
| Parameter | Traditional Solar Inverter | HC1066EH48L Hybrid Inverter Solar |
| Battery Connection | Usually unavailable | 48V battery supported |
| Backup Function | Limited | ≤10ms backup switching |
| PV Tracking | Single MPPT common | Dual MPPT |
| Generator Support | Limited | Supported |
| Parallel Expansion | Rare | Up to 15 units |
| Outdoor Installation | Depends on enclosure | IP65 protection |
| Energy Management | Basic conversion | Intelligent multi-source control |
Solar PV energy supplies household loads. Excess PV energy beyond load demand charges the 48V battery bank. The system does not export to the utility grid.
When solar power is unavailable or insufficient, the inverter discharges the battery to supply household loads. If the battery reaches its preset depth of discharge (DoD), utility grid power supplies the load demand.
The system maximizes solar self-consumption and prevents energy backflow into the utility grid.

The inverter synchronizes with utility frequency and exports surplus solar power, functioning as a standard grid-interactive single phase inverter.
Runs independently from battery and PV input, suitable for remote sites without utility connection.
Combines both: prioritizes solar and battery use during the day, switches to grid or battery seamlessly at night or during outages.
Safety is critical for residential solar energy systems.
The HC1060EH48L integrates multiple hardware and software protection functions.
These include:
The inverter complies with international safety and EMC requirements, including:
These standards ensure reliable operation in global solar markets.
The HC1066EH48L is ideal for modern homes requiring:
For small businesses, the inverter provides:
Suitable locations:
The inverter is suitable for areas with unstable grid infrastructure.
System combination:
PV + Battery + Generator + HC1066EH48L
provides reliable electricity access.
| System Component | Recommended Specification |
| Hybrid Inverter | HC1066EH48L x 1 |
| PV Array Capacity | 700W PV Modules x 16 |
| Battery Voltage | 51.2V 314AH x 1 |
| Battery Type | LiFePO4 Lithium Battery |
| Battery Current | Up to 120A |
| Backup Switching | ≤10ms |
| Monitoring | WiFi / 4G / RS485 / CAN |
| Model | HC1066EH48L |
| Phase Configuration | Single Phase Input / Single Phase Output |
| Parallel Capability | Supported, up to 15 units |
| Recommended Max. PV Input Power | 13.2KW(6.6KW + 6.6KW) |
| Rated Output Power | 6.6KW |
| Dimension (DxWxH) | 320x170x440 mm |
| Net Weight (Kg) | 15.0 |
| PV INPUT (DC) | |
| Max. PV Input Voltage | 500VDC |
| PV Start-up Voltage | 90VDC |
| MPPT Voltage Range | 120VDC – 425VDC |
| MPPT Voltage @ Full Load | 370VDC – 425VDC |
| Max. PV Input Current | 18A + 18A |
| Max. PV Short-Circuit Current | 26A + 26A |
| MPPT Trackers / Strings per MPPT | 2/1 + 1 |
| AC INPUT (GRID/GENERATOR) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| AC Voltage Range | 150VAC – 290VAC |
| Grid Frequency Range | 50Hz: 45Hz-55Hz / 60Hz: 55Hz-65Hz |
| Max. AC Input Current | 40A |
| AC OUTPUT (LOAD) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| Rated Output Current | 28.7A |
| Output Frequency | 50Hz/60Hz ± 0.5Hz |
| Grid Connection Type | Single Phase ( L + N + PE ) |
| THDu | < 2% (Linear load) |
| Power Factor | > 0.99 @Rated Power (Adjustable 0.8 Leading to 0.8 Lagging) |
| Transfer Time | ≤ 10ms |
| Output Waveform | Pure sine wave |
| Overload Capability | 101%-110% @30s, >110% @10s |
| BATTERY& CHARGER | |
| Compatible Battery Types | Lead-acid / Gel or Lithium-ion |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40 – 60VDC |
| Max. Charge / Discharge Current | 120A |
| EFFICIENCY | |
| Max. Efficiency | 97.60% |
| European Efficiency | 96.50% |
| MPPT Efficiency | > 99% |
| PROTECTION | |
| Integrated Protections | Grid/Battery Over/Undervoltage Protection, Grid Over/Underfrequency Protection,
Output Short Circuit/Overload Protection, PV Reverse Polarity Alarm, Battery Overcurrent Protection (Charge/Discharge), Insulation Resistance Monitoring, Residual Current Monitoring Unit (RCMU) / Ground Fault Protection |
| COMMUNICATION & MONITORING | |
| Communication Interface | Standard: RS485/CAN; Optional: 4G/WiFi/GPRS/Bluetooth/LAN |
| Display | Touch LCD + LED Indicator |
| GENERAL | |
| Topology | Transformerless (Non-isolated) |
| Cooling Method | Intelligent Fan Cooling |
| Installation Type | Wall-mounted |
| Generator Compatibility | Supported (Generator Port / Input) |
| ENVIRONMENT | |
| Ingress Protection | IP65 |
| Noise Level | < 55dB |
| Humidity | 0~95% RH (Non-condensing) |
| Altitude | < 3000m (<2000m Recommended, Derating Above 2000m) |
| Operating Temperature | -40°C to 60°C (Power Derating Above 45°C) |
| Warranty | 5 Years standard |
| CERTIFICATES | |
| Safety & EMC Standards | IEC/EN 61000-6-1/3 , IEC/EN 61000-3-11/12, EN 62920, IEC 62109-1,
IEC 62109-2, IEC 62321 |