Split Phase Solar Inverter | 12000W | 120V/240V 60Hz | 48VDC | Max. Charging: 200A
GRANKIA HS2120UH48L high efficiency split phase hybrid inverter 12kw ensures seamless power management between solar, grid, and battery sources. The hybrid inverter 12kw delivers a 120V/240V split-phase pure sine wave output. It provides clean and stable electricity. This power is safe for sensitive electronics and heavy-duty appliances alike. Engineered for high efficiency and resilience, the split phase hybrid inverter redefines smart energy conversion.
Whether connected to a solar array, utility grid, or energy storage system, it guarantees reliable and adaptive power delivery. The hybrid inverter 12kw is also environmentally conscious. This empowers users to achieve true energy independence.
Feature-rich Time-of-Use (ToU) settings allow you to program charging and discharging cycles. Save money by storing energy when rates are low and using it during peak hours. The split phase hybrid inverter 12kw offers a unique battery-free operation mode.
The system can run loads directly using a combined supply from PV and the grid. This setup provides flexibility during battery maintenance or staged system upgrades.
Pure Sine Wave Output – 120V / 240V Split Phase
Delivers clean, stable AC power ideal for sensitive electronics and household appliances. The split-phase configuration supports both 120V and 240V loads simultaneously—perfect for North American and similar electrical systems.
Time-of-Use (TOU) Charging & Discharging Settings
It intelligently schedules battery charging from the grid during off-peak hours. It also discharges during peak-rate periods. This helps users significantly reduce electricity bills while supporting grid stability.
Battery-Free Operation with PV + Grid Combined Supply
The solar system operates efficiently even without batteries. It intelligently combines solar and grid power to support loads. This is a cost-effective solution for users prioritizing immediate savings and simplicity.
Advanced Hybrid Functionality
Grid-interactive (sell back excess solar power when allowed)
Automatic generator start (dry contact for 2-wire start)
Time-of-use scheduling & programmable charge/discharge periods
Built-in smart load management port (for non-essential loads)
Independent Generator Interface with Intelligent Load Support
Features a dedicated generator input that automatically coordinates with solar and battery sources. The split phase solar inverter intelligently manages loads during generator operation, optimizing fuel consumption and runtime.
Two-Level Anti-Backflow Protection for Grid Safety
Complies with stringent grid interconnection standards through dual-layer anti-backfeed control. This prevents unwanted power export to the grid. This is essential for regions with strict net-metering or zero-export regulations.

| No. | Parts | Description |
| 1 | Solar Inverter | Split-phase solar inverter. |
| 2 | Battery Bank | Select the appropriate battery model according to the inverter–battery compatibility list. |
| 3 | PV String | A PV string consists of multiple photovoltaic modules connected in series. |
| 4 | Battery Breaker | Users should prepare a 2P DC circuit breaker. |
| 5 | AC Breaker | The AC breaker specifications for the LOAD and GRID must be the same for a given inverter model. The AC breaker should be provided by the end user. |
| 6 | SPDT Switch | To ensure the load can be powered by the grid during inverter maintenance, install an SPDT switch. |
| 7 | Generator | The generator’s maximum output power must be equal to or greater than the inverter’s rated power. |

| 1.LED Indicator | 2.LCD Display | 3.AC Input Breaker | 4.Label |
| 5.PV Input Switch | 6.Ground(PE) | 7.Power On/Off | 8.WiFi/GPRS (Option) |
| 9.AC Input Terminal | 10.Second Output / Generator Input Terminal | 11.Main Output Terminal | 12.COM Communication Port |
| 13.BMS Communication Port | 14.Dry Contact | 15.Battery Terminal | 16.PV Input Terminal (PV1/PV2) |

Solar panels generate power and feed it into the inverter.
Priority of power usage:
Solar power supplies household loads first.
Excess solar power charges the batteries.
Remaining energy is exported to the grid (feed-in).
Surplus energy can be exported to the grid (if enabled).
Solar input is unavailable.
The inverter supplies loads using:
The grid can also charge the batteries according to settings (e.g. time-of-use mode).
The utility grid is disconnected.
The inverter automatically switches to backup mode.
Loads are powered by:
Solar panels (if available), and
Batteries.
Critical loads continue to run without interruption, ensuring power reliability during outages.
The 12kW split-phase hybrid inverter has two-level anti-backflow (anti-backfeed) protection. This ensures grid safety. It is particularly important in regions with strict regulations against exporting excess solar power to the utility grid (e.g., areas with zero-export or net-metering restrictions).
Here’s how this dual-layer grid safety protection works:
| Model | HS2120UH48L |
| Rated Power | 12000W |
| Parallel Capability | No |
| AC / GENERATOR INPUT | |
| Nominal Voltage | 120Vac – 240Vac |
| Voltage Range | 90Vac-140Vac(L-N), 180Vac-280Vac(L-L) |
| Frequency Range | 50Hz: 47-55Hz / 60Hz: 57-65Hz, ±0.3Hz |
| AC OUTPUT | |
| Nominal Voltage | 120Vac / 240Vac |
| Frequency | 50Hz / 60Hz ±0.3Hz(Auto) |
| Rated Current | 50.0A |
| Max. Efficiency | 92.00% |
| Transfer Time | 10ms |
| Waveform | Pure Sine Wave |
| BATTERY | |
| Battery Type | Lead-acid / Gel / LiFePO4 |
| Battery Rated Voltage | 48VDC |
| Battery Voltage Range | 40-60VDC |
| Default Charging Current | 60A |
| CHARGER | |
| Max. PV Array Power | 7500W + 7500W |
| MPPT Range @ Operating Voltage | 90-450VDC |
| Max. PV Array Open Circuit Voltage | 500VDC |
| Max. Solar Charge Current | 200A |
| AC Charge Current | 120A |
| Maximum Charge Current | 200A |
| ENVIRONMENT | |
| Installation Method | Wall-mounted |
| Humidity | 5%~95%(No condensation) |
| Operation Temperature | -10℃ ~ 55℃ |
| Storage Temperature | -20℃ ~ 60℃ |
| Altitude | ≤2000m** |
| INTERFACE | |
| Communication | RS485/CAN, Optional Wi-Fi/GPRS |
| Display | LCD + LED |
| MECHANICAL | |
| Dimension, WxDxH (mm) | 465x140x620 |
| Weight (Kg) | 28.0 |
| CERTIFICATIONS | |
| Certificate | FCC, UL |
| Standard | FCC47 CFR Port 15, UL1741, TSCA, CA65 |