Hybrid Solar Inverter | 3300W | 48VDC | Max. PV Power: 3600W | Max. Charge Current: 60A
GRANKIA GIS3.3K-48L 3300w 48v solar inverter single phase for home backup, it is designed for residential backup power and solar energy applications. It supports up to 3600W PV input, a 60A maximum solar charging current, lead-acid/GEL/LiFePO4 batteries, pure sine wave output, and grid-tied operation. Its compact wall-mounted design simplifies residential installation.
Operating with a 48VDC battery system, this inverter integrates solar energy conversion, battery charging, and AC power management into one compact unit.
It supports grid-tied operation and accepts both solar PV and AC/generator input. This provides homeowners with multiple energy sources for daily electricity consumption and backup power.
What makes this configuration practical for residential applications?
Its 3600W maximum PV array capacity, 60A solar charging capability, and compatibility with three major battery chemistries provide flexibility when designing a home backup system.
The GIS3.3K-48L 3300w 48v solar inverter is particularly suitable for:
Residential solar backup systems.
Small off-grid solar installations.
Homes requiring battery-supported backup power.
Solar systems using 48V LiFePO4 batteries.
Applications requiring single-phase 220V/230V AC output.
3300W rated AC output with 220V/230V single-phase operation.
The 48v solar inverter provides a stable power output for residential electrical loads. Its 220V/230V output configuration supports common single-phase household electrical systems.
Homeowners can use solar and stored battery energy to support essential household appliances during grid interruptions or normal solar operation.
| Electrical Parameter | Specification |
|---|---|
| Rated Output Power | 3300W |
| Rated Output Current | 14.3A |
| Nominal AC Voltage | 220V/230V |
| Output Voltage Regulation | ±4% |
| Frequency | 50Hz/60Hz |
| Power Factor | Unity |
The 3300W capacity makes this 48V solar inverter suitable for small and medium residential backup configurations.
However, actual load compatibility depends on the combined running power and startup requirements of connected appliances.

Supports up to 3600W maximum PV array power, with a 90–450VDC MPPT operating range.
The wide MPPT voltage range provides flexibility when configuring solar panel strings. The maximum PV open-circuit voltage is 500VDC.
System designers can configure the PV array according to available installation space, solar panel electrical characteristics, and daily energy requirements.
| PV Input Parameter | Specification |
|---|---|
| Maximum PV Array Power | 3600W |
| Maximum PV Open-Circuit Voltage | 500VDC |
| MPPT Operating Voltage | 90–450VDC |
| Number of MPPT Trackers | 1 |
| Number of PV Strings | 1 |
The inverter uses one MPPT tracker and one PV string input.
This configuration is suitable for relatively straightforward residential rooftop solar installations.
Important design consideration: The total PV string open-circuit voltage, including temperature-related voltage increases, must remain below 500VDC. The operating voltage must also stay within the specified MPPT range.
Maximum solar charging current of 60A.
The charging system supports relatively high current delivery to a 48V battery bank, helping convert available solar energy into stored electrical energy.
Homeowners can store more available daytime solar energy for evening consumption and backup applications, subject to PV generation and battery charging limits.
| Charging Parameter | Specification |
|---|---|
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40–60VDC |
| Default Charging Current | 30A |
| Maximum Solar Charging Current | 60A |
| Maximum Total Charging Current | 60A |
| Maximum AC Charging Current | 30A |
The inverter supports solar and AC charging.
The maximum combined charging current is 60A, not 90A. The solar and AC charging currents must operate within the inverter’s total charging limit.
Battery charging settings should also follow the battery manufacturer’s recommended voltage, current, and temperature limits.
Compatible with three battery types: lead-acid, GEL, and lithium iron phosphate (LiFePO4).
The 48V battery architecture gives installers and system integrators flexibility in battery selection.
Users can select a battery configuration based on initial investment, expected cycling frequency, maintenance requirements, and backup duration.
| Battery Type | Typical Application | Selection Consideration |
|---|---|---|
| Lead-Acid | Basic residential backup | Initial cost and maintenance |
| GEL | Stationary backup applications | Charging voltage and current limits |
| LiFePO4 | Frequent solar cycling | BMS compatibility and communication |
LiFePO4 batteries are commonly selected for residential solar storage because of their cycle-life characteristics and integrated battery management systems.
The GIS3.3K-48L 3300w 48v solar inverter supports RS485 communication. However, the exact lithium battery communication protocol and BMS compatibility must be confirmed before installation.
Do not assume that every 48V lithium battery is automatically compatible.

Supports AC input from the grid or a compatible generator.
The 48v solar inverter accepts an AC input voltage range of 170–280VAC and automatically detects 50Hz or 60Hz frequency operation.
Users have an additional charging and power supply option when solar generation is insufficient.
| AC Input Parameter | Specification |
|---|---|
| Nominal Voltage | 220V/230V |
| Acceptable Voltage | 170–280VAC |
| 50Hz Frequency Range | 47–55Hz |
| 60Hz Frequency Range | 57–65Hz |
| Maximum AC Charging Current | 30A |
This flexibility is particularly useful for residential solar systems installed in areas with unstable grid electricity or limited sunlight.
Generator compatibility should be checked against the generator’s voltage regulation, frequency stability, and available output capacity.
Integrated RS485 communication with optional Wi-Fi or GPRS connectivity.
The communication interface provides a foundation for system monitoring and communication with compatible external devices.
Installers and system operators can monitor operating information and potentially perform remote system management when supported communication accessories and software are available.
| Communication Feature | Specification |
|---|---|
| Standard Communication | RS485 |
| Optional Connectivity | Wi-Fi / GPRS |
| Display | LCD |
| Status Indicators | LED |
The optional connectivity provides additional monitoring possibilities.
Before deployment, confirm the availability of the corresponding monitoring platform, communication protocol, and accessories.
The following table summarizes the main electrical and installation parameters of the GIS3.3K-48L.
| Parameter | Specification |
|---|---|
| Model | GIS3.3K-48L |
| Rated Output Power | 3300W |
| Battery Voltage | 48VDC |
| AC Output | 220V/230V |
| Phase | Single Phase (L+N+PE) |
| Maximum PV Array Power | 3600W |
| Maximum PV Voltage | 500VDC |
| MPPT Voltage Range | 90–450VDC |
| Maximum Solar Charging Current | 60A |
| Maximum AC Charging Current | 30A |
| Maximum Combined Charging Current | 60A |
| Surge Power | 6600VA |
| Output Waveform | Pure Sine Wave |
| Maximum Efficiency | ≥93.8% |
| Transfer Time | 10ms |
| Battery Compatibility | Lead-acid / GEL / LiFePO4 |
| Communication | RS485 |
| Protection Degree | IP21 |
| Dimensions | 269 × 100 × 372mm |
| Weight | 7.2kg |
The GIS3.3K-48L supports two charging sources.
| Charging Feature | Solar Charging | AC Charging |
|---|---|---|
| Charging Source | PV panels | Grid/generator |
| Maximum Current | 60A | 30A |
| Energy Source | Solar energy | AC electricity |
| Main Application | Solar energy storage | Backup battery charging |
The maximum combined charging current is 60A.
This distinction matters when configuring simultaneous charging from PV and AC sources.

To enable the photovoltaic grid-connected power generation function on the 48v hybrid solar inverter, you configure Parameter [27] in the LCD settings menu.
Before changing grid-tie settings, make sure your grid connection and protection devices are properly wired and comply with local utility rules, as feeding power back to the grid involves live AC mains and high-voltage DC solar inputs.
Press the ESC key on the display panel to enter the Settings menu.
Press the UP and DOWN keys until parameter code 27 (Photovoltaic grid-connected power generation function) is selected.
Press ENTER to enter parameter editing mode, then use UP and DOWN to choose your desired grid-tie option:
Press ESC to exit the Settings menu and return to normal operation monitoring.
When running without a battery on the hybrid inverter (with Parameter [27] set to TOG or TOL), the unit relies on its battery-less output/bypass capability and grid connection to keep loads running and handle solar energy.
When running without a battery on the hybrid inverter, whether you should choose TOG or TOL in Parameter [27] depends on whether you want to export excess solar power back to the utility grid or simply share your local load between solar and the grid.
| Feature | TOG | TOL |
| Definition | When the battery is filled or not connected to the cell, the photovoltaic energy of the excess local load is fed to the grid. | The load power is provided by the PV and utility grid power. |
| Excess Solar Power | Sent back into the utility grid when solar generation exceeds local load demand. | Not explicitly defined as feeding back to the grid; focuses on powering the local load using both PV and utility power. |
| Best Use Case Without a Battery | Grid-export / net-metering setups where exporting surplus solar energy is allowed and desired. | Self-consumption setups where PV and utility power jointly supply your connected appliances without exporting to the grid. |
Correct installation is necessary to achieve the specified electrical performance and maintain system safety.
The GIS3.3K-48L specifications reference the following standards:
| Standard | Scope |
|---|---|
| IEC 62109-1 | Safety of power converters for photovoltaic systems – General requirements |
| IEC 62109-2 | Particular requirements for inverter safety |
| IEC/EN 61000-6-1 | EMC immunity for residential, commercial and light-industrial environments |
| IEC/EN 61000-6-3 | EMC emission requirements for residential environments |
| IEC 62321 | Determination of regulated substances in electrotechnical products |
The product specification also lists CE and RoHS certifications/compliance.
For international projects, buyers should request the relevant declarations and test documentation to verify the exact applicable standards and certification scope.
Installation Considerations
Before commissioning, installers should verify:
Correct battery polarity and DC cable sizing.
Appropriate DC and AC circuit protection.
PV string voltage under minimum-temperature conditions.
Battery charging and discharging limits.
Protective earthing and grounding.
Adequate ventilation and installation clearance.
Compatibility with the local grid voltage and frequency.
Its specified operating temperature range is -10°C to 55°C.
| Model | GIS3.3K-48L |
| Rated Output Power | 3300W |
| PHASE | Single phase, L+N+PE |
| Grid-tied Operation | Supported |
| Parallel Capability | No |
| PV INPUT (DC) | |
| Max. PV Array Power | 3600W |
| Max. Solar Charging Current | 60A |
| Max. PV Open Circuit Voltage | 500VDC |
| MPPT Operating Voltage Range | 90-450VDC |
| Number of MPPT Trackers / Strings | 1/1 |
| AC / GENERATOR INPUT | |
| Nominal Voltage | 220VAC/230VAC |
| Acceptable Voltage Range | 170VAC – 280VAC |
| Frequency Range | 50Hz: 47-55Hz / 60Hz: 57-65Hz (Auto-sensing) |
| Max. AC Charging Current | 30A |
| AC OUTPUT | |
| Rated Output Power | 3300W |
| Rated Current | 14.3A |
| Surge Power | 6600VA |
| Nominal Voltage | 220VAC/230VAC ± 4% |
| Frequency | 50Hz / 60Hz ±0.3Hz(Auto-sensing) |
| Waveform | Pure Sine Wave |
| Transfer Time | 10ms |
| Power Factor | Unity Power Factor |
| Max. Efficiency | ≥ 93.8% |
| BATTERY | |
| Compatible Battery Types | Lead-acid / Gel / LiFePO4 |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40-60VDC |
| Default Charging Current | 30A |
| Max. Total Charging Current | 60A |
| INTERFACE & COMMUNICATION | |
| Communication Ports | RS485 |
| Optional Models | Wi-Fi / GPRS |
| Display | LCD + LED Indicators |
| ENVIRONMENT | |
| Installation Method | Wall-mounted |
| Operating Temperature | -10℃ ~ 55℃ |
| Storage Temperature | -20℃ ~ 60℃ |
| Operating Humidity | 5%~95%(No condensation) |
| Max. Operating Altitude | ≤2000m (Derating above 2000m) |
| Protection Degree | IP21 (Indoor installation) |
| MECHANICAL | |
| Dimension, WxDxH (mm) | 269x100x372 |
| Weight (Kg) | 7.2 |
| CERTIFICATIONS | |
| Safety & EMC Certificates | CE, RoHS |
| Compliance Standards | IEC/EN 61000-6-1/3, IEC 62109-1, IEC 62109-2, IEC 62321 |