IP65 Hybrid Solar Inverter | 12.0KW | 2MPPTs: 36A + 36A | 48VDC | Max. Charging: 250A
The HC1120EH48L 12kW hybrid solar inverter is a single-phase 48V energy conversion platform with 24kW recommended PV input, dual MPPT, up to 97.6% efficiency, 260A battery discharge capability, IP65 protection, and ≤10ms transfer time for high-power residential backup and solar-storage applications.
The HC1120EH48L is designed for homes requiring substantially more power than a conventional 5–8kW inverter.
As a 12kW hybrid solar inverter, it combines PV conversion, battery charging and discharging, grid/generator input, and backup power management in one wall-mounted unit.
Its architecture supports:
This configuration makes the HC1120EH48L suitable for high-demand homes, villas, workshops, small commercial buildings, and backup systems with large PV arrays.

The HC1120EH48L 12kw hybrid solar inverter features an ultra-wide dual tracker MPPT configuration designed for high-capacity solar arrays.
Supporting double its rated AC output in total PV input power, the unit enables aggressive over-provisioning to maximize morning and late-afternoon energy harvesting.
Dual independent MPPT trackers (12kW + 12kW handling up to 36A each) maximize power yield across multi-orientation roof installations.
Operating from 90VDC to 525VDC ensures earlier system startup and extended daily power production.
Supports a maximum short-circuit current of 40A per MPPT tracker, accommodating high-power 600W+ bifacial modules.
| Technical Parameter | Engineering Specification | Operational Significance |
| Recommended Max. PV Power | 24kW (12kW + 12kW) | Enables a 2:1 DC/AC ratio to maximize energy yield in off-peak sun hours |
| Max. Input / Startup Voltage | 525VDC / 90VDC | Provides high operating headroom and early morning activation |
| MPPT Voltage Range (Full Load) | 90VDC – 525VDC (300VDC – 430VDC) | Ensures maximum MPPT efficiency (>99%) across summer and winter thermal shifts |
| Tracker / String Configuration | 2 MPPTs / 2+2 Strings (40A + 40A Short Circuit) | Allows versatile stringing without external combiner boxes |
By utilizing a high-capacity 48V battery inverter topology, the system achieves maximum low-voltage electrical safety without requiring costly high-voltage battery racks.
Heavy internal busbars support continuous high-current discharge to comfortably run heavy household inductive loads without triggering thermal protection.
Compatible with Lithium-ion, Gel, and Lead-acid chemistry across a 40VDC–60VDC operational window.
Delivers up to 260A continuous discharge current and 250A adjustable charging current.
Provides clean voltage output with Total Harmonic Distortion (THDu) below 2%, protecting delicate microelectronics.
Switchover transfer time under 10ms prevents server rebooting or home appliance disruption during power grid failure.
| System Parameter | Technical Specification | Performance Benchmark |
| Nominal AC Output Voltage | 220V / 230V / 240VAC (Single Phase L+N+PE) | Broad utility compatibility with customizable frequency (50/60Hz ±5Hz) |
| Continuous / Surge Current | 57.4A Continuous Output Current | Easily starts heavy HVAC systems and multi-horsepower motor loads |
| Overload Tolerances | 100–110% (3 min), 110–125% (1 min), >125% (10 sec) | Robust transient surge absorption avoids nuisance trips |
| System Efficiency | 97.60% Max / 96.50% European Efficiency | Transformerless design maintains low idle power self-consumption (<25W) |
The HC1120EH48L 12kw hybrid solar inverter is designed for applications where backup loads can exceed the practical output range of smaller residential inverters.
Its 12kW rated output can support multiple household load categories simultaneously, depending on the site’s electrical design.
Typical loads may include:
The inverter provides a pure sine wave output, making it suitable for sensitive electronic and motor-driven loads when the complete electrical installation is correctly designed.

The unit functions seamlessly as a grid-tied hybrid inverter, offering flexible power management modes including self-consumption priority, peak shaving, and time-of-use discharge.
Advanced grid-interactive firmware monitors utility power quality while preventing unexpected backfeeding during outages.
Directly accepts external generator power and provides signal contacts for automatic generator start (AGS).
Delivers a power factor >0.99 at rated power (adjustable 0.8 leading to 0.8 lagging) and low harmonic distortion (THDi <3%).
Features a touch LCD display alongside standard RS485/CAN interfaces with optional 4G, WiFi, GPRS, LAN, and Bluetooth dongles.
The HC1120EH48L 12kW hybrid solar inverter uses an IP65-rated enclosure.
According to the supplied specification, the inverter is designed for operation from -25°C to +60°C, with power derating above 45°C.
Other environmental specifications include:
At elevations above 2000m, derating should be considered during system design.
Likewise, operation above 45°C requires attention to available output power and installation ventilation.
The 12kW hybrid solar inverter integrates multiple electrical protection functions.
These include:
The supplied compliance references include IEC 62109-1, IEC 62109-2, EN/IEC 50549-10, IEC 60529, EN/IEC 61000-6-1, EN/IEC 61000-6-3, and RoHS.
These standards address areas such as inverter safety, grid interaction, enclosure protection, electromagnetic compatibility, and hazardous-substance restrictions.
Final certification and grid approval should always be verified against the target country’s requirements and the exact production configuration.
| Model | HC1120EH48L |
| Product type | 12kW hybrid solar inverter |
| Phase | Single-phase input / single-phase output |
| Rated output | 12kW |
| Recommended PV input | 24kW |
| Battery voltage | 48VDC |
| PV maximum voltage | 525VDC |
| MPPT range | 90–525VDC |
| MPPT efficiency | >99% |
| Max. battery discharge | 260A |
| Max. battery charge | 250A |
| Max. efficiency | 97.60% |
| AC output | 220/230/240VAC |
| Transfer time | ≤10ms |
| Waveform | Pure sine wave |
| Protection | IP65 |
| Communication | RS485/CAN; optional wireless/network interfaces |
| Generator | Supported |
| Cooling | Intelligent fan |
| Installation | Wall-mounted |
| Weight | 35.6kg |
| Warranty | 5 years standard |
A 12kW hybrid solar inverter is appropriate when the property’s continuous and peak electrical demand is beyond the practical range of smaller inverter platforms.
Typical applications include:
Large homes and villas can use the 12kW output to supply multiple household circuits while integrating battery storage and rooftop PV.
Where backup loads include air conditioning, pumps, refrigeration, and other high-demand equipment, the 12kW rating provides greater load capacity than typical 5–8kW systems.
The 24kW recommended PV input makes the HC1120EH48L suitable for oversized PV arrays designed to maximize daily solar energy production.
Generator compatibility provides an additional energy source for areas with unreliable grid supply or extended backup requirements.
| Model | HC1120EH48L |
| Phase Configuration | Single Phase Input / Single Phase Output |
| Recommended Max. PV Input Power | 24KW(12KW + 12KW) |
| Rated Output Power | 12.0KW |
| Dimension (WxDxH) | 474x246x835 mm |
| Net Weight (Kg) | 35.6 |
| PV INPUT (DC) | |
| Max. PV Input Voltage | 525VDC |
| PV Start-up Voltage | 90VDC |
| MPPT Voltage Range | 90VDC – 525VDC |
| MPPT Voltage @ Full Load | 300VDC – 430VDC |
| Max. PV Input Current | 36A + 36A |
| Max. PV Short-Circuit Current | 40A + 40A |
| MPPT Trackers / Strings per MPPT | 2/2 + 2 |
| AC INPUT (GRID/GENERATOR) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| AC Voltage Range | 90VAC – 280VAC (Configurable) |
| Grid Frequency Range | 50Hz: 45Hz-55Hz / 60Hz: 55Hz-65Hz |
| Max. AC Input Current | 52.1A |
| THDi | < 3% |
| DC Current Injection | < 0.5%In |
| AC OUTPUT (LOAD) | |
| Nominal AC Voltage | 220VAC/230VAC/240VAC |
| Max. Output Current | 57.4A |
| Output Frequency | 50Hz/60Hz ± 5Hz |
| Grid Connection Type | Single Phase ( L + N + PE ) |
| THDu | < 2% (Linear load) |
| Power Factor | > 0.99 @Rated Power (Adjustable 0.8 Leading to 0.8 Lagging) |
| Transfer Time | ≤ 10ms |
| Output Waveform | Pure sine wave |
| Overload Capability | 100%-110% @3mins, 110%-125% @1min, >125% @10s |
| BATTERY& CHARGER | |
| Compatible Battery Types | Lead-acid / Gel or Lithium-ion |
| Nominal Battery Voltage | 48VDC |
| Battery Voltage Range | 40 – 60VDC |
| Max. Discharge Current | 260A |
| Max. Charge Current | 250A(1-250A adjustable) |
| EFFICIENCY | |
| Max. Efficiency | 97.60% |
| European Efficiency | 96.50% |
| MPPT Efficiency | > 99% |
| PROTECTION | |
| Integrated Protections | PV Reverse Polarity Protection/Alarm, Over/Under Voltage Protection, Over/Under Frequency Protection, Output Short-Circuit & Overload Protection, Anti-Islanding Protection, Battery Charge/Discharge Overcurrent Protection, Leakage Current Protection, Insulation Resistance Monitoring, Ground Fault Protection |
| COMMUNICATION & MONITORING | |
| Communication Interface | Standard: RS485/CAN; Optional: 4G/WiFi/GPRS/Bluetooth/LAN |
| Display | Touch LCD + LED Indicator |
| GENERAL | |
| Topology | Transformerless (Non-isolated) |
| Cooling Method | Intelligent Fan Cooling |
| Installation Type | Wall-mounted |
| Generator Compatibility | Supported (Generator Port / Input) |
| Self-Consumption | < 25W |
| ENVIRONMENT | |
| Ingress Protection | IP65 |
| Noise Level | < 58dB |
| Humidity | 0~95% RH (Non-condensing) |
| Altitude | 4000m (<2000m Recommended, Derating Above 2000m) |
| Operating Temperature | -25°C to +60°C (Power Derating Above 45°C) |
| Warranty | 5 Years standard |
| CERTIFICATES | |
| Safety & EMC Standards | IEC 62109-2 2011,IEC 62109-1 2010,EN/IEC 50549-10,EC 60529:1989/AMD:2013,GB/T 4208-2017, EN/IEC 61000-6-3:2021, EN 61000-3-12:2011, EN/IEC 61000-3-12:2019, EN/IEC 61000-6-1:2019, RoHS |